PURPOSE: The most frequent therapy of hydrocephalus is implantation of ventriculoperitoneal shunts for diverting cerebrospinal into the peritoneal cavity. We compared two adjustable valves, proGAV and proGAV 2.0, for complications resulting in revision surgery.

METHODS

Four hundred patients undergoing primary shunt implantation between 2014 and 2020 were analyzed for overall revision rate, 1-year revision rate, and revision-free survival observing patient age, sex, etiology of hydrocephalus, implantation site, prior diversion of cerebrospinal fluid, and cause of revision.

RESULTS

All data were available of all 400 patients (female/male 208/192). Overall, 99 patients underwent revision surgery after primary implantation. proGAV valve was implanted in 283 patients, and proGAV 2.0 valves were implanted in 117 patients. There was no significant difference between the two shunt valves concerning revision rate (p = 0.8069), 1-year revision rate (p = 0.9077), revision-free survival (p = 0.6921), and overall survival (p = 0.3232). Regarding 1-year revision rate, we observed no significant difference between the two shunt valves in pediatric patients (40.7% vs 27.6%; p = 0.2247). Revision operation had to be performed more frequently in pediatric patients (46.6% vs 24.8%; p = 0.0093) with a significant higher number of total revisions with proGAV than proGAV 2.0 (33 of 59 implanted shunts [55.9%] vs. 8 of 29 implanted shunts [27.6%]; p = 0.0110) most likely due to longer follow-up in the proGAV-group. For this reason, we clearly put emphasis on analyzing results regarding 1-year revision rate.

CONCLUSION

According to the target variables we analyzed, aside from lifetime revision rate in pediatric patients, there is no significant difference between the two shunt valves.

Для цитирования: Busse Lewin-Caspar, Dubinski Daniel, Gessler Florian, Dinc Nazife, Konczalla Jürgen, Czabanka Marcus, Senft Christian, Freiman Thomas M, Baumgarten Peter. Retrospective comparison of long-term functionality and revision rate of two different shunt valves in pediatric and adult patients.. Acta neurochirurgica. 2023. DOI: 10.1007/s00701-023-05719-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.