Quality-controlled dose reduction of full-leg radiography in patients with knee malalignment.

Kloth Jost Karsten, Neumann Regina, von Stillfried Eva, Stiller Wolfram, Kauczor Hans-Ulrich, Ewerbeck Volker, Weber Marc-André

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Digital plain radiographs of the full leg are frequently performed examinations of children and young adults. Thus, the objective of this work was to reduce the radiation exposure dependent on specific indications, and to determine objective quality-control criteria to ensure accurate assessment.

MATERIALS AND

METHODS

Institutional review board approval and informed consent of all participants were obtained. In this prospective, randomized controlled, blinded, two-armed single-center study, 288 evaluable patients underwent plain radiography of the full leg with standard and reduced doses. The evaluation of the plain radiographs was conducted using the following criteria: mechanical axis, leg length, and maturation of the epiphyseal plate. Two blinded radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score of 3 or more points or all criteria with 2 points, the radiograph was scored as "not assessable". The study was designed as a non-inferiority trial.

RESULTS

Eleven (3.8%) examined X-rays were scored as not assessable. The rate of non-assessable radiographs with 33% reduced dose was significantly not inferior to the rate of non-assessable radiographs with standard dose. The evaluation of the quality criteria was dose independent.

CONCLUSIONS

Full-leg plain radiography in patients with knee malalignment can be performed at 33% reduced dose without loss of relevant diagnostic information.

Для цитирования: Kloth Jost Karsten, Neumann Regina, von Stillfried Eva, Stiller Wolfram, Kauczor Hans-Ulrich, Ewerbeck Volker, Weber Marc-André. Quality-controlled dose reduction of full-leg radiography in patients with knee malalignment.. Skeletal radiology. 2014. DOI: 10.1007/s00256-014-2004-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.