OBJECTIVES

We sought to determine the significance of bright CD45 expression on mast cells in cases of systemic mastocytosis vs mast cells in bone marrows uninvolved by systemic mastocytosis and compare this CD45 expression with CD25 and CD2 expression on mast cells.

METHODS

Multiparameter flow cytometry was performed on 31 cases of systemic mastocytosis and 70 bone marrow cases that were not involved by systemic mastocytosis. Bright expression of CD45 was defined as more than 20% of CD117+ mast cells showing brighter CD45 expression than the average expression level of lymphocytes.

RESULTS

Mast cells with bright CD45 expression were seen in 26 systemic mastocytosis cases and three bone marrows uninvolved by systemic mastocytosis (sensitivity, 84%; specificity, 96%). CD25 alone had a greater sensitivity (100%) but lower specificity (93%) compared with bright CD45 for identifying abnormal mast cells, while CD2 alone had lower sensitivity but higher specificity. To reach a specificity of 100%, CD25 together with bright CD45 on mast cells was the optimal combination to detect cases of systemic mastocytosis.

CONCLUSIONS

A combination of bright CD45 and CD25 appears to specifically identify abnormal mast cells in cases of systemic mastocytosis. Further studies will be necessary to confirm these results.

Для цитирования: Chisholm Karen M, Merker Jason D, Gotlib Jason R, Gitana Gary, Lefterova Martina, Zehnder James L, George Tracy I, Arber Daniel A, Ohgami Robert S. Mast cells in systemic mastocytosis have distinctly brighter CD45 expression by flow cytometry.. American journal of clinical pathology. 2015. DOI: 10.1309/ajcpz3j4geeyirra.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.