DOI 10.1002/mp.17895

Медицинская библиотека · Medical physics · 2025

Transformer model based on Sonazoid contrast-enhanced ultrasound for microvascular invasion prediction in hepatocellular carcinoma.

Qin Qiong, Pang Jinshu, Li Jingdan, Gao Ruizhi, Wen Rong, Wu Yuquan, Liang Li, Que Qiao, Liu Changwen, Peng Jinbo, Lv Yun, He Yun, Lin Peng, Yang Hong

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Microvascular invasion (MVI) is strongly associated with the prognosis of patients with hepatocellular carcinoma (HCC).

PURPOSE: To evaluate the value of Transformer models with Sonazoid contrast-enhanced ultrasound (CEUS) in the preoperative prediction of MVI.

METHODS

This retrospective study included 164 HCC patients. Deep learning features and radiomic features were extracted from arterial and Kupffer phase images, alongside the collection of clinicopathological parameters. Normality was assessed using the Shapiro-Wilk test. The Mann‒Whitney U-test and least absolute shrinkage and selection operator algorithm were applied to screen features. Transformer, radiomic, and clinical prediction models for MVI were constructed with logistic regression. Repeated random splits followed a 7:3 ratio, with model performance evaluated over 50 iterations. The area under the receiver operating characteristic curve (AUC, 95% confidence interval [CI]), sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), decision curve, and calibration curve were used to evaluate the performance of the models. The DeLong test was applied to compare performance between models. The Bonferroni method was used to control type I error rates arising from multiple comparisons. A two-sided p-value of < 0.05 was considered statistically significant.

RESULTS

In the training set, the diagnostic performance of the arterial-phase Transformer (AT) and Kupffer-phase Transformer (KT) models were better than that of the radiomic and clinical (Clin) models (p < 0.0001). In the validation set, both the AT and KT models outperformed the radiomic and Clin models in terms of diagnostic performance (p < 0.05). The AUC (95% CI) for the AT model was 0.821 (0.72-0.925) with an accuracy of 80.0%, and the KT model was 0.859 (0.766-0.977) with an accuracy of 70.0%. Logistic regression analysis indicated that tumor size (p = 0.016) and alpha-fetoprotein (AFP) (p = 0.046) were independent predictors of MVI.

CONCLUSIONS

Transformer models using Sonazoid CEUS have potential for effectively identifying MVI-positive patients preoperatively.

Для цитирования: Qin Qiong, Pang Jinshu, Li Jingdan, Gao Ruizhi, Wen Rong, Wu Yuquan, Liang Li, Que Qiao, Liu Changwen, Peng Jinbo, Lv Yun, He Yun, Lin Peng, Yang Hong. Transformer model based on Sonazoid contrast-enhanced ultrasound for microvascular invasion prediction in hepatocellular carcinoma.. Medical physics. 2025. DOI: 10.1002/mp.17895.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.