Crystal analyser-based X-ray phase contrast imaging in the dark field: implementation and evaluation using excised tissue specimens.

Ando Masami, Sunaguchi Naoki, Wu Yanlin, Do Synho, Sung Yongjin, Louissaint Abner, Yuasa Tetsuya, Ichihara Shu, Gupta Rajiv

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

We demonstrate the soft tissue discrimination capability of X-ray dark-field imaging (XDFI) using a variety of human tissue specimens.

METHODS

The experimental setup for XDFI comprises an X-ray source, an asymmetrically cut Bragg-type monochromator-collimator (MC), a Laue-case angle analyser (LAA) and a CCD camera. The specimen is placed between the MC and the LAA. For the light source, we used the beamline BL14C on a 2.5-GeV storage ring in the KEK Photon Factory, Tsukuba, Japan.

RESULTS

In the eye specimen, phase contrast images from XDFI were able to discriminate soft-tissue structures, such as the iris, separated by aqueous humour on both sides, which have nearly equal absorption. Superiority of XDFI in imaging soft tissue was further demonstrated with a diseased iliac artery containing atherosclerotic plaque and breast samples with benign and malignant tumours. XDFI on breast tumours discriminated between the normal and diseased terminal duct lobular unit and between invasive and in-situ cancer.

CONCLUSIONS

X-ray phase, as detected by XDFI, has superior contrast over absorption for soft tissue processes such as atherosclerotic plaque and breast cancer.

KEY POINTS: • X-ray dark field imaging (XDFI) can dramatically increase sensitivity of phase detection. • XDFI can provide enhanced soft tissue discrimination. • With XDFI, abnormal anatomy can be visualised with high spatial/contrast resolution.

Для цитирования: Ando Masami, Sunaguchi Naoki, Wu Yanlin, Do Synho, Sung Yongjin, Louissaint Abner, Yuasa Tetsuya, Ichihara Shu, Gupta Rajiv. Crystal analyser-based X-ray phase contrast imaging in the dark field: implementation and evaluation using excised tissue specimens.. European radiology. 2013. DOI: 10.1007/s00330-013-3021-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.