A loop-mediated isothermal amplification test for yaws: a multi-country diagnostic accuracy evaluation.

Handley Becca L, González-Beiras Camila, Tchatchouang Serges, Hugues Kouadio Aboh, Basing Laud Antony, Sylla Aboubacar, Kouamé-Sina Mireille S, Amanor Ivy, Ndzomo Philippe, Aloumba Axel, Bakheit Mohammed, Müller Claudia, Borst Nadine, Landmann Emelie, Gmoser Helena, Härpfer Tamara, Becherer Lisa, Lüert Simone, Frischmann Sieghard, Burl Sarah, Tabah Earnest Njih, Crucitti Tania, Kouadio Adingra Tano, Arhinful Daniel Kojo, Awondo Patrick, Kakou Solange Ngazoa, Eyangoh Sara, Addo Kennedy Kwasi, Knauf Sascha, Mitjà Oriol, Harding-Esch Emma Michèle, Marks Michael

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

To meet the WHO target of eradicating yaws by 2030, highly sensitive and specific diagnostic tools are needed. A multiplex Treponema pallidum-Haemophilus ducreyi loop-mediated isothermal amplification (TPHD-LAMP) test holds promise as a near-patient diagnostic tool for yaws and H ducreyi. We conducted a prospective evaluation in Cameroon, Côte d'Ivoire, Ghana, and the Republic of the Congo to determine the diagnostic accuracy of the TPHD-LAMP test, as well as to assess its acceptability, feasibility, and cost.

METHODS

Active case searching within schools and communities was used to locate participants with clinically suspicious laws-like lesions. Individuals with serologically confirmed active yaws provided paired lesion swabs between March, 2021, and April, 2023. For each participant, one swab was tested with the TPHD-LAMP at a local district laboratory and the other with reference quantitative PCR (qPCR) tests conducted at national reference laboratories. The primary outcome was TPHD-LAMP test sensitivity and specificity compared with qPCR. Laboratory technicians were interviewed using a multiple-choice survey to gauge acceptability and feasibility of the TPHD-LAMP test. Costs of each test were calculated.

FINDINGS: Of 3085 individuals with at least one suspected yaws lesion, 531 (17%) were serologically confirmed. We enrolled 493 participants with seropositive yaws and a further 32 with negative serology. The sensitivity of the TPHD-LAMP test for detecting T pallidum was 63% (95% CI 56-70) and the specificity was 66% (95% CI 61-71). Sensitivity and specificity for T pallidum improved to 73% (63-82; p=0·0065) and 75% (68-80; p=0·0003), respectively, in H ducreyi-negative samples. Interviews highlighted challenges in user-friendliness and practicality of the TPHD-LAMP test. The cost of the test per sample was one third of that of qPCR, although the TPHD-LAMP test entailed higher costs to establish the assay.

INTERPRETATION: This was the first multi-country diagnostic evaluation of a molecular test for yaws. The TPHD-LAMP testing, in its current form, falls short of the WHO target product profile criteria for yaws diagnostics. These findings highlight the importance of assessing new diagnostics in real-world conditions to ensure their suitability for programmatic use.

FUNDING: The EDCTP2 programme supported by the EU.

Для цитирования: Handley Becca L, González-Beiras Camila, Tchatchouang Serges, Hugues Kouadio Aboh, Basing Laud Antony, Sylla Aboubacar, Kouamé-Sina Mireille S, Amanor Ivy, Ndzomo Philippe, Aloumba Axel, Bakheit Mohammed, Müller Claudia, Borst Nadine, Landmann Emelie, Gmoser Helena, Härpfer Tamara, Becherer Lisa, Lüert Simone, Frischmann Sieghard, Burl Sarah, Tabah Earnest Njih, Crucitti Tania, Kouadio Adingra Tano, Arhinful Daniel Kojo, Awondo Patrick, Kakou Solange Ngazoa, Eyangoh Sara, Addo Kennedy Kwasi, Knauf Sascha, Mitjà Oriol, Harding-Esch Emma Michèle, Marks Michael. A loop-mediated isothermal amplification test for yaws: a multi-country diagnostic accuracy evaluation.. The Lancet. Global health. 2024. DOI: 10.1016/s2214-109x(24)00324-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.