MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.28324

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2019

X-ray fused with MRI guidance of pre-selected transcatheter congenital heart disease interventions.

Grant Elena K, Kanter Joshua P, Olivieri Laura J, Cross Russell R, Campbell-Washburn Adrienne, Faranesh Anthony Z, Cronin Ileen, Hamann Karin S, O'Byrne Michael L, Slack Michael C, Lederman Robert J, Ratnayaka Kanishka

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To determine whether X-ray fused with MRI (XFM) is beneficial for select transcatheter congenital heart disease interventions.

BACKGROUND

Complex transcatheter interventions often require three-dimensional (3D) soft tissue imaging guidance. Fusion imaging with live X-ray fluoroscopy can potentially improve and simplify procedures.

METHODS

Patients referred for select congenital heart disease interventions were prospectively enrolled. Cardiac MRI data was overlaid on live fluoroscopy for procedural guidance. Likert scale operator assessments of value were recorded. Fluoroscopy time, radiation exposure, contrast dose, and procedure time were compared to matched cases from our institutional experience.

RESULTS

Forty-six patients were enrolled. Pre-catheterization, same day cardiac MRI findings indicated intervention should be deferred in nine patients. XFM-guided cardiac catheterization was performed in 37 (median age 8.7 years [0.5-63 years]; median weight 28 kg [5.6-110 kg]) with the following prespecified indications: pulmonary artery (PA) stenosis (n = 13), aortic coarctation (n = 12), conduit stenosis/insufficiency (n = 9), and ventricular septal defect (n = 3). Diagnostic catheterization showed intervention was not indicated in 12 additional cases. XFM-guided intervention was performed in the remaining 25. Fluoroscopy time was shorter for XFM-guided intervention cases compared to matched controls. There was no significant difference in radiation dose area product, contrast volume, or procedure time. Operator Likert scores indicated XFM provided useful soft tissue guidance in all cases and was never misleading.

CONCLUSIONS

XFM provides operators with meaningful three-dimensional soft tissue data and reduces fluoroscopy time in select congenital heart disease interventions.

Для цитирования: Grant Elena K, Kanter Joshua P, Olivieri Laura J, Cross Russell R, Campbell-Washburn Adrienne, Faranesh Anthony Z, Cronin Ileen, Hamann Karin S, O'Byrne Michael L, Slack Michael C, Lederman Robert J, Ratnayaka Kanishka. X-ray fused with MRI guidance of pre-selected transcatheter congenital heart disease interventions.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2019. DOI: 10.1002/ccd.28324.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.