m+Medelevator.RU
← Поиск публикаций
Pediatric pulmonology · 2025

Predictors of Bronchodilator Response on Oscillometry and Spirometry in School-Age Children With Bronchopulmonary Dysplasia.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lee Julia X, Ryan Morgan E, Sun Bob Z, Beam Kristyn, Hayden Lystra P, Dahlberg Suzanne E, Gaffin Jonathan M

Аннотация

This study aimed to identify predictors of bronchodilator response (BDR) on oscillometry and spirometry for school-age children with bronchopulmonary dysplasia (BPD). We hypothesized that clinical and neonatal characteristics influence BDR. Participants aged 6-12 years enrolled in the Air Quality, Environment and Respiratory Outcomes in BPD (AERO-BPD) observational study performed pre- and post-bronchodilator oscillometry and spirometry. Measures included forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, airway resistance at 5 Hertz (Hz, R5), resistance between 5 Hz and 19 Hz (R5-19), resonant frequency (Fres), reactance at 5 Hz (X5), and area under the curve between Fres and X5 (AX). Spirometric BDR was defined as pre- minus post-bronchodilator measures relative to predicted. Oscillometry BDR was defined by pre- minus post-bronchodilator relative to pre-bronchodilator. Positive BDR response was defined as change in (Δ)AX < -80%, ΔR5 < -40%, ΔX5 > +50%, ΔFEV1 > +10% and ΔFVC > +10%. Logistic regression tested predictors of BDR. Among 119 participants who performed paired pre- and post-bronchodilator oscillometry and spirometry, median pre-bronchodilator z-scores of all measures were normal (within +/-1.64). More participants had BDR on spirometry than oscillometry (33% per FEV1, 10% per FVC, 9% per X5, 7% per R5, and 3% per AX). Inter-device measures overall correlated weakly. Lower pre-bronchodilator FEV1 was strongly associated with increased odds of BDR on both devices, while no neonatal variables showed evidence of associations. In school-aged children with BPD, approximately one-third exhibited BDR. Spirometry showed greater rates of BDR than oscillometry. Lower pre-bronchodilator FEV1 was linked with higher likelihood of BDR. Neonatal history does not predict BDR.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты