DOI 10.1016/j.jped.2019.04.006

Медицинская библиотека · Jornal de pediatria · 2019

Functional echocardiography training in the neonatal intensive care unit: comparing measurements and results with the pediatric cardiologist.

Zamith Marina Maccagnano, Figueira Simone de Araujo Negreiros, Oliveira Allan Chiaratti de, Metolina Cristiane, Castro Junia Sampel de, Santos Cristina Nunes Dos, Capo Ana Leticia de Oliveira Abrahão de, Moisés Valdir Ambrósio

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Functional echocardiography is a valuable tool in the neonatal intensive care unit, but training programs are not standardized. The aim was to report an functional echocardiography training program for neonatologists and to describe the agreement of their measurements with the pediatric cardiologist.

METHODS

Functional echocardiography training lasted 32h. After training program, the neonatologists performed functional echocardiography in the neonatal intensive care unit and were required to measure left cardiac chambers dimensions, left ventricle systolic function, right and left ventricular output, ductus arteriosus diameter, and flow pattern. Images were recorded by the equipment and reviewed offline by the pediatric cardiologist. The Bland-Altman test was used for quantitative variables and the kappa test, for qualitative variables.

RESULTS

Twenty-two trained neonatologists performed 100 functional echocardiography exams. Ductus arteriosus identification and flow pattern had substantial agreement (kappa=0.91 and 0.88, respectively), as well as its diameter (mean difference=0.04mm). The mean difference for the aortic root was -1.2mm; left atrium, 0.60mm; left ventricle diastolic diameter, -0.90mm; left ventricle systolic diameter, -0.30mm. Shortening fraction and ejection fraction correlated well with broad limits of agreement, -2.96% (14.88; -20.82%) and --3.43% (15.54; -22.40%), respectively. Right and left ventricular output had broad limits of agreement, 16.69mL/kg/min (222.76; -189.37) and 23.57mL/kg/min (157.88; -110), respectively. There was good agreement between interpretations of normal or low cardiac output (76.7% for right ventricular output; 75.7% for left ventricular output).

CONCLUSION

This functional echocardiography training program enabled neonatologists to obtain adequate skills in performing the images, obtaining good agreement with the cardiologist in simple hemodynamic measurements and ductus arteriosus evaluation.

Для цитирования: Zamith Marina Maccagnano, Figueira Simone de Araujo Negreiros, Oliveira Allan Chiaratti de, Metolina Cristiane, Castro Junia Sampel de, Santos Cristina Nunes Dos, Capo Ana Leticia de Oliveira Abrahão de, Moisés Valdir Ambrósio. Functional echocardiography training in the neonatal intensive care unit: comparing measurements and results with the pediatric cardiologist.. Jornal de pediatria. 2019. DOI: 10.1016/j.jped.2019.04.006.