Аннотация

PURPOSE: During anesthesia, maneuvers which cause the least disturbance of cerebral oxygenation with the greatest decrease in intracranial pressure would be most beneficial to patients with intracranial hypertension. Both head-up tilt (HUT) and hyperventilation are used to decrease brain bulk, and both may be associated with decreases in cerebral oxygenation. In this observational study, our null hypothesis was that the impact of HUT and hyperventilation on cerebral tissue oxygen saturation (SctO2) and cerebral blood volume (CBV) are comparable.

METHODS

Surgical patients without neurological disease were anesthetized with propofol-remifentanil. Before the start of surgery, frequency-domain near-infrared spectroscopy was used to measure SctO2 and CBV at the supine position, at the 30° head-up and head-down positions, as well as during hypoventilation and hyperventilation.

RESULTS

Thirty-three patients were studied. Both HUT and hyperventilation induced small decreases in SctO2 [3.5 (2.6)%; P < 0.001 and 3.0 (1.8)%; P < 0.001, respectively] and in CBV [0.05 (0.07) mL x 100 g(-1); P < 0.001 and 0.06 (0.05) mL x 100 g(-1); P < 0.001, respectively]. There were no differences between HUT to 30° and hyperventilation to an end-tidal carbon dioxide (ETCO2) of 25 mmHg (from 45 mmHg) in both SctO2 (P = 0.3) and CBV (P = 0.4).

DISCUSSION: The small but statistically significant decreases in both SctO2 and CBV caused by HUT and hyperventilation are comparable. There was no correlation between the decreases in SctO2 and CBV and the decreases in blood pressure and cardiac output during head-up and head-down tilts. However, the decreases in both SctO2 and CBV correlate with the decreases in ETCO2 during ventilation adjustment.

Для цитирования: Meng Lingzhong, Mantulin William W, Alexander Brenton S, Cerussi Albert E, Tromberg Bruce J, Yu Zhaoxia, Laning Kathleen, Kain Zeev N, Cannesson Maxime, Gelb Adrian W. Head-up tilt and hyperventilation produce similar changes in cerebral oxygenation and blood volume: an observational comparison study using frequency-domain near-infrared spectroscopy.. Canadian journal of anaesthesia = Journal canadien d'anesthesie. 2012. DOI: 10.1007/s12630-011-9662-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.