Retrospective patient-specific intravascular brachytherapy dosimetry using optical coherence tomography imaging.

Rahbaran Maryam, Bergmark Brian A, Croce Kevin J, Tsui James M G, Devlin Phillip M, Enger Shirin A

СтатьяПеревод в очереди

Аннотация

PURPOSE: Drug-eluting stents fail in up to 20% of patients. In failed cases, intravascular brachytherapy (IVBT) is administered with β-emitting 90Sr90Y through a guidewire. Current clinical dosimetry is water-based, neglecting attenuation from patient-specific materials such as plaques, stents, and the off-centered guidewire, leading to a discrepancy between prescribed and delivered dose. This study retrospectively performed patient-specific IVBT dose calculations using Optical Coherence Tomography (OCT) to quantify uncertainties in clinical dosimetry.

METHODS AND MATERIALS: Dose calculations on OCT images from ten patients were performed using RapidBrachyIVBT, a Monte Carlo-based dose calculation software. Heterogeneities, including guidewire(s), stents, and fibrotic and calcified plaques, were contoured and assigned material properties; surrounding tissue was modeled as smooth muscle. Absorbed dose to water and medium were calculated. The prescribed dose to water was 18.4 or 23 Gy at 2 mm from the source, depending on lumen diameter. The dose homogeneity index was defined as the ratio of the maximum to the minimum dose in the target volume.

RESULTS

When heterogeneities were included, median maximum dose attenuation was 76.7% (75.0-77.1) in the artery segment and 56.2% (52.2-65.1) in the target volume. The median dose homogeneity index increased from 1.29 in water to 2.93 (2.44-3.33) with patient-specific materials. The guidewire produced asymmetric dose distributions in all patients, with the greatest attenuation where it opposed thick calcified plaques.

CONCLUSIONS

Standard water-based IVBT dosimetry is inaccurate due to dose-attenuating materials present during treatment. Personalized, image-guided IVBT planning that accounts for patient-specific heterogeneities may improve treatment accuracy and clinical outcomes.

Для цитирования: Rahbaran Maryam, Bergmark Brian A, Croce Kevin J, Tsui James M G, Devlin Phillip M, Enger Shirin A. Retrospective patient-specific intravascular brachytherapy dosimetry using optical coherence tomography imaging.. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). 2026. DOI: 10.1016/j.ejmp.2026.105858.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.