Feasibility and safety of monopolar diathermy as an alternative to clip ligation in laparoscopic Fowler-Stephens orchiopexy.

AbouZeid Amr Abdelhamid, Moussa Manal Hassan, Shalaby Mohamed Sameh, Safoury Hesham Soliman, El-naggar Osama, Hay Sameh Abdel

СтатьяПеревод в очереди

Аннотация

PURPOSE: The aims of the study were to study the effect of Fowler-Stephens orchiopexy (FSO) on testicular histology and to assess the feasibility of using monopolar diathermy as an alternative to clip ligation during laparoscopic FSO.

PATIENTS AND

METHODS

The study included 20 patients with 20 intraabdominal testes and short vessels managed by laparoscopic-staged FSO. Biopsies were taken from intraabdominal testes during the first and second stages of the procedure for histologic comparison. The patients in the study were divided into 2 groups according to the method of dividing the testicular vessels in stage 1. The first 13 patients (group A) were managed by clip ligation of the vessels, whereas monopolar diathermy was used in the following 7 patients (group B).

RESULTS

Biopsy findings at stage 2 revealed an overall reduction in both the total number of germ cells per tubule and mean diameter of seminiferous tubules, whereas there was no statistically significant difference between the results in groups A and B.

CONCLUSION

The seminiferous cells can withstand (survive) dividing the main blood supply of the testis during FSO. The monopolar diathermy can be used as an alternative to clipping during laparoscopic procedures, having the advantages of lower expenses and using smaller instruments.

Для цитирования: AbouZeid Amr Abdelhamid, Moussa Manal Hassan, Shalaby Mohamed Sameh, Safoury Hesham Soliman, El-naggar Osama, Hay Sameh Abdel. Feasibility and safety of monopolar diathermy as an alternative to clip ligation in laparoscopic Fowler-Stephens orchiopexy.. Journal of pediatric surgery. 2012. DOI: 10.1016/j.jpedsurg.2012.04.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.