Primary replacement for the management of exposed orbital implant.

Curragh David S, Kamalarajah Srikandan, Lacey Brendan, White Stephen T, McNab Alan A, Kalantzis George, Dolman Peter J, Selva Dinesh, Rajak Saul N

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

Purpose: We present a series of primary orbital implant replacement for cases of implant exposure to describe our experience of this one-staged surgical approach.

Methods

This study reports on a one-stage technique which involved the removal of the exposed implant or dermis fat graft (DFG) and insertion of a secondary (replacement) in the same procedure, with a variety of materials, including autologous tissue. Re-exposure in a socket where a DFG was placed was defined as a new defect in the newly epithelialized conjunctiva or dehiscence of the dermis-conjunctiva junction. All cases of primary replacement for the management of exposed orbital implant, porous and non-porous, were included, even when there were clinical signs suggestive of infection. The primary outcome was the rate of re-exposure, requiring additional surgical procedures. Infection following primary replacement was a secondary outcome.

Results

Seventy-eight patients had primary replacement for the management of an exposed orbital implant. 6.4% had re-exposure at a mean follow-up of 49.7 months (9.1% for ball implants and 4.5% for DFG). The rate of exposure was higher in those with prior signs of infection than those without (8% vs. 3.6%). Re-exposure occurred in 4.5% of cases with DFG implantation, 4.3% of cases with non-porous implants and in 20% of cases with porous implants.

Conclusion

Primary replacement for management of exposed orbital implant, porous and non-porous, has a high rate of successful outcome even in cases with presumed or confirmed infection.

Для цитирования: Curragh David S, Kamalarajah Srikandan, Lacey Brendan, White Stephen T, McNab Alan A, Kalantzis George, Dolman Peter J, Selva Dinesh, Rajak Saul N. Primary replacement for the management of exposed orbital implant.. Orbit (Amsterdam, Netherlands). 2019. DOI: 10.1080/01676830.2019.1573262.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.