MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.accpm.2020.10.014

Медицинская библиотека · Anaesthesia, critical care & pain medicine · 2020

A novel, automated, quantification of abnormal lung parenchyma in patients with COVID-19 infection: Initial description of feasibility and association with clinical outcome.

Noll Eric, Soler Luc, Ohana Mickael, Ludes Pierre-Olivier, Pottecher Julien, Bennett-Guerrero Elliott, Veillon Francis, Goichot Bernard, Schneider Francis, Meyer Nicolas, Diemunsch Pierre

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

Ground-glass opacities are the most frequent radiologic features of COVID-19 patients. We aimed to determine the feasibility of automated lung volume measurements, including ground-glass volumes, on the CT of suspected COVID-19 patients. Our goal was to create an automated and quantitative measure of ground-glass opacities from lung CT images that could be used clinically for diagnosis, triage and research.

DESIGN

Single centre, retrospective, observational study.

MEASUREMENTS: Demographic data, respiratory support treatment (synthetised in the maximal respiratory severity score) and CT-images were collected. Volume of abnormal lung parenchyma was measured with conventional semi-automatic software and with a novel automated algorithm based on voxels X-Ray attenuation. We looked for the relationship between the automated and semi-automated evaluations. The association between the ground-glass opacities volume and the maximal respiratory severity score was assessed.

MAIN

RESULTS

Thirty-seven patients were included in the main outcome analysis. The mean duration of automated and semi-automated volume measurement process were 15 (2) and 93 (41) min, respectively (p=8.05*10-8). The intraclass correlation coefficient between the semi-automated and automated measurement of ground-glass opacities and restricted normally aerated lung were both superior to 0.99. The association between the automated measured lung volume and the maximal clinical severity score was statistically significant for the restricted normally aerated (p=0.0097, effect-size: -385mL) volumes and for the ratio of ground-glass opacities/restricted normally aerated volumes (p=0.027, effect-size: 3.3).

CONCLUSION

The feasibility and preliminary validity of automated impaired lung volume measurements in a high-density COVID-19 cluster was confirmed by our results.

Для цитирования: Noll Eric, Soler Luc, Ohana Mickael, Ludes Pierre-Olivier, Pottecher Julien, Bennett-Guerrero Elliott, Veillon Francis, Goichot Bernard, Schneider Francis, Meyer Nicolas, Diemunsch Pierre. A novel, automated, quantification of abnormal lung parenchyma in patients with COVID-19 infection: Initial description of feasibility and association with clinical outcome.. Anaesthesia, critical care & pain medicine. 2020. DOI: 10.1016/j.accpm.2020.10.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.