MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-2008-1027433

Медицинская библиотека · RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin · 2008

[Evaluation of malformations of the fetal central nervous system using fetal MRI].

Blondin D, Schaper J, Klee D, Reihs T, Hammer R, Mödder U, Messing-Jünger M

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

PURPOSE: Ultrasound as the primary prenatal screening modality is used to detect fetal anomalies. Aim of the study was to prove the additional value of fetal magnetic resonance imaging (MRI).

MATERIALS AND

METHODS

In 25 pregnant women (age 30.6 +/- 4.8; 24 single and one twin pregnancy) with pathologic findings of the central nervous system detected by obstetric ultrasound, a fetal MRI was performed. All sequences (T2w-HASTE, TRUEFISP, T 1w-FLASH 2D, DWI) were performed using the breath-hold technique. The results were compared to postnatal MRI or ultrasound scan findings and tested for correlation with the clinical course and development of these children.

RESULTS

Three to seven days after ultrasound, an MRI of all 26 fetuses without sedation was performed (26.6 +/- 4.0 GW). One healthy twin was not included in this study. MRI confirmed the ultrasonographic diagnosis in 7 cases. Compared to ultrasound, an additional pathology could be detected by MRI in 8 cases. In 10 cases ultrasound diagnosis was overruled by MRI. Prenatal MRI findings were confirmed by postnatal imaging in 18 children. The clinical course was predictable in 8 of 15 cases, depending on the pathology detected. Three newborns died in the perinatal period.

CONCLUSION

Our results showed that fetal MRI has a high impact as an addition to ultrasound in evaluating congenital CNS pathology. Fetal MRI has become a helpful device for advising parents. However, clinical course and development still cannot be predicted based on MRI findings alone.

Для цитирования: Blondin D, Schaper J, Klee D, Reihs T, Hammer R, Mödder U, Messing-Jünger M. [Evaluation of malformations of the fetal central nervous system using fetal MRI].. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2008. DOI: 10.1055/s-2008-1027433.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.