MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjci/jet145

Медицинская библиотека · European heart journal. Cardiovascular Imaging · 2013

Assessment of right ventricular volumes in hypoplastic left heart syndrome by real-time three-dimensional echocardiography: comparison with cardiac magnetic resonance imaging.

Bell Aaron, Rawlins Debbie, Bellsham-Revell Hannah, Miller Owen, Razavi Reza, Simpson John

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Accurate assessment of right ventricular (RV) volumes and function is important in patients with hypoplastic left heart syndrome (HLHS). We prospectively sought to determine the reproducibility of three-dimensional (3D) echocardiography and its agreement with cardiac magnetic resonance imaging (CMR) in HLHS.

METHODS AND

RESULTS

Twenty-eight patients underwent CMR followed immediately by transthoracic 3D echocardiography under general anaesthesia. Semi-automated border detection software was used to determine echocardiographic RV volumes. Inter- and intra-observer variability, correlation and levels of agreement between techniques were determined. The median age was 0.37 years (0.18-9.28 years) and weight 6.24 kg (3.42-32.50 kg). Intra- and inter-observer variability was excellent for both techniques. Median (range) measurements for 3D echocardiography and CMR were; end-diastolic volume (EDV) 23.6 mL (6.5-63.2) and 30.6 mL (11.8-87.9), end-systolic volume (ESV) 12.6 mL (3.7-37.0) and 14.9 mL (5.8-33.9), stroke volume (SV) 11.2 mL (2.8-33.0) and 17.1 mL (6.0-54.1), ejection fraction (EF) 48.2% (31.2-64.9), and 56.5% (42.7-72.2). Correlation coefficients were r = 0.85, 0.84, 0.83, and 0.74, respectively (P < 0.01 for all). Volumetric data were expressed as a percentage of the echocardiographic volume to CMR volume. When compared with CMR, 3D echocardiography underestimated EDV, ESV and SV by 26.7% (SD ± 20.2), 10.6% (±28.1), and 37.5% (±20.1), respectively. The difference in volume appeared largest at low ventricular volumes. EF was 8.3% (±7.3) lower by 3D echocardiography compared with CMR.

CONCLUSION

Both 3D echocardiography and CMR volumes appear highly reproducible. Measurements obtained by 3D echocardiography are significantly lower than those obtained by CMR, with wide limits of agreement such that these two methods cannot be used interchangeably.

Для цитирования: Bell Aaron, Rawlins Debbie, Bellsham-Revell Hannah, Miller Owen, Razavi Reza, Simpson John. Assessment of right ventricular volumes in hypoplastic left heart syndrome by real-time three-dimensional echocardiography: comparison with cardiac magnetic resonance imaging.. European heart journal. Cardiovascular Imaging. 2013. DOI: 10.1093/ehjci/jet145.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.