MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00431-023-05320-6

Медицинская библиотека · European journal of pediatrics · 2023

Effectiveness of ultrasound-guided peripheral arterial cannulation in neonates, including very low birth weight infants who are conventionally difficult-to-cannulate: a case series.

Okada Yuki, Kido Takahiro, Takeuchi Syusuke, Hanaki Mai, Nakamura Yuri, Nagafuji Motomichi, Kanai Yu, Hitaka Daisuke, Miyazono Yayoi, Takada Hidetoshi

СтатьяПеревод в очереди

Аннотация

The effectiveness of ultrasound-guided peripheral arterial cannulation (UGPAC) in children has been increasingly been reported. However, to the best of our knowledge, there have been no reports of UGPAC in neonates, including very low birth weight infants (VLBWIs). In this study, we aimed to retrospectively review the results of UGPAC in neonates, including VLBWIs, and assess its effectiveness. This case series was conducted in a tertiary neonatal intensive care unit (NICU) in Japan. We included neonates aged below 28 days who underwent UGPAC in our NICU between April 2021 and October 2022. We extracted the following data from medical records and analysed it retrospectively: patient age (days), postconceptional age, patient weight at the time of cannulation, number of punctures using the conventional technique before ultrasound guidance was performed and number of punctures with the ultrasound-guided technique until successful cannulation. A total of 27 UGPACs were performed in 19 neonates, including 14 cannulations in 10 VLBWIs. In infants weighing > 1500 g and VLBWIs, the success rate within the first three punctures was 100% (13/13) and 79% (11/14), respectively. Overall, 41% (11/27) of UGPACs were performed following failed punctures using conventional methods, with a 100% success rate within the first three attempts. In all cases, no apparent adverse events, such as hypothermia, were noted.

Conclusions

Our results suggest that UGPAC had a high success rate in neonates, including VLBWIs. Further studies are required to compare the effectiveness of UGPAC with conventional methods in neonates. What is Known: • The use of ultrasound guidance for arterial cannulation is recommended in children. • Ultrasound-guided peripheral arterial cannulation (UGPAC) in neonates, including very low birth weight infants (VLBWIs), has not been reported. What is New: • UGPAC in neonates, including VLBWIs, was performed with a high success rate; approximately 40% of UGPACs were performed after the failure of the conventional methods. • This study suggested the effectiveness of UGPAC in neonates, including VLBWIs.

Для цитирования: Okada Yuki, Kido Takahiro, Takeuchi Syusuke, Hanaki Mai, Nakamura Yuri, Nagafuji Motomichi, Kanai Yu, Hitaka Daisuke, Miyazono Yayoi, Takada Hidetoshi. Effectiveness of ultrasound-guided peripheral arterial cannulation in neonates, including very low birth weight infants who are conventionally difficult-to-cannulate: a case series.. European journal of pediatrics. 2023. DOI: 10.1007/s00431-023-05320-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.