MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12350-019-01681-4

Медицинская библиотека · Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019

Initial experience with regadenoson stress positron emission tomography in patients with left bundle branch block: Low prevalence of septal defects and high accuracy for obstructive coronary artery disease.

Meredith Dane, Cremer Paul C, Harb Serge C, Xu Bo, Mentias Amgad, Jaber Wael A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Assessing for coronary artery disease (CAD) in patients with left bundle branch block (LBBB) is difficult with noninvasive cardiac imaging. Few studies report the prevalence of LBBB associated septal-apical perfusion defects using regadenoson stress on Positron Electron Tomography (PET) imaging.

METHODS AND

RESULTS

We identified 101 consecutive patients with baseline LBBB, and without known CAD, who underwent rest-stress regadenoson PET. Investigators have the ability to prospectively identify studies, whose quality is limited by LBBB artifact. With the infusion of regadenoson, resting to peak stress heart rate rose from a median of 78 to 93 BPM. Despite this, LBBB perfusion artifacts were not identified in any studies. 10 individuals had both regadenoson SPECT and PET within 1 year. 3 of the 10 SPECT studies had LBBB artifacts, all of which were not seen on subsequent PET. 21 patients with PET had subsequent coronary angiography. Of these, 9 PETs were without significant inducible ischemia, and angiogram was without flow-limiting disease. 3 PETs identified inducible ischemia, but did not have flow-limiting disease on angiogram. 9 PETs identified inducible ischemia and had flow-limiting disease on angiogram.

CONCLUSIONS

In patients with LBBB undergoing regadenoson PET stress imaging, artifactual septal perfusion defects are rare.

Для цитирования: Meredith Dane, Cremer Paul C, Harb Serge C, Xu Bo, Mentias Amgad, Jaber Wael A. Initial experience with regadenoson stress positron emission tomography in patients with left bundle branch block: Low prevalence of septal defects and high accuracy for obstructive coronary artery disease.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2019. DOI: 10.1007/s12350-019-01681-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.