Systolic-dicrotic notch pressure difference can identify tachycardic patients with septic shock at risk of cardiovascular decompensation following pharmacological heart rate reduction.
Аннотация
BACKGROUND
During sepsis, heart rate (HR) reduction could be a therapeutic target, but identification of responders (non-compensatory tachycardia) and non-responders (compensatory for 'fixed' stroke volume [SV]) is challenging. We tested the ability of the difference between systolic and dicrotic pressure (SDPdifference), which reflects the coupling between myocardial contractility and a given afterload, in discriminating the origin of tachycardia.
METHODS
In this post hoc analysis of 45 patients with septic shock with persistent tachycardia, we characterised features of haemodynamic response focusing on SDPdifference, classifying patients according to variations in arterial dP/dtmax after 4 h of esmolol administration to maintain HR <95 beats min-1. A cut-off value of 0.9 mm Hg ms-1 was used for group allocation.
RESULTS
After reducing HR, arterial dP/dtmax remained above the cut-off in 23 patients, whereas it decreased below the cut-off in 22 patients (from 0.99 [0.37] to 0.63 [0.16] mm Hg ms-1; mean [SD], P<0.001). At baseline, patients with decreased dP/dtmax after esmolol had lower SDPdifference than those with higher dP/dtmax (40 [19] vs 53 [16] mm Hg, respectively; P=0.01). The SDPdifference remained unchanged after esmolol in the higher dP/dtmax group (49 [16] mm Hg), whereas it decreased significantly in patients with lower dP/dtmax (29 [11] mm Hg; P<0.001). In the latter, the HR reduction resulted in a significant cardiac output reduction with unchanged SV, whereas in patients with higher dP/dtmax SV increased (from 48 [12] to 67 [14] ml; P<0.001) with maintained cardiac output.
CONCLUSIONS
A decrease in SDPdifference could discriminate between compensatory and non-compensatory tachycardia, revealing a covert loss of myocardial contractility not detected by conventional echocardiographic parameters and deteriorating after HR reduction with esmolol.
CLINICAL TRIAL REGISTRATION: NCT02188888.