MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00234-006-0098-8

Медицинская библиотека · Neuroradiology · 2006

Evaluation of CSF flow patterns of posterior fossa cystic malformations using CSF flow MR imaging.

Yildiz Harun, Yazici Zeynep, Hakyemez Bahattin, Erdogan Cuneyt, Parlak Mufit

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Differential radiologic diagnosis of cystic malformations of the posterior fossa is often difficult with conventional imaging techniques because of overlapping features of these entities. Posterior fossa cystic malformations occupy the cerebrospinal fluid (CSF) spaces. They may create secondary dynamic effects on the movements of CSF. The aim of this study was to investigate CSF flow alterations in posterior fossa cystic malformations with CSF flow MR imaging.

METHODS

The study included 40 patients with cystic malformations of the posterior fossa. The patients underwent cardiac-gated phase-contrast cine MR imaging. CSF flow was qualitatively evaluated using an in-plane phase-contrast sequence in the midsagittal plane. The MR images were displayed in a closed-loop cine format.

RESULTS

Twelve of the patients had communicating arachnoid cyst, seven had non-communicating arachnoid cyst, ten had mega cisterna magna, six had Dandy-Walker malformation, two had Dandy-Walker variant, and three had Blake's pouch cyst. CSF flow MR imaging indicated the regions of no, slow or higher flow, direction of flow, and abnormal cystic fluid motion. Each malformation displayed a distinct CSF flow pattern.

CONCLUSION

Phase-contrast cine MR imaging for CSF flow evaluation may be a useful adjunct to routine MR imaging in the evaluation of the cystic malformations of the posterior fossa because it can improve the specificity in differentiating such malformations.

Для цитирования: Yildiz Harun, Yazici Zeynep, Hakyemez Bahattin, Erdogan Cuneyt, Parlak Mufit. Evaluation of CSF flow patterns of posterior fossa cystic malformations using CSF flow MR imaging.. Neuroradiology. 2006. DOI: 10.1007/s00234-006-0098-8.