MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-022-04559-2

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2022

Impact of stem profile on the revisability and the need for osteotomy in well-fixed cemented revision total knee arthroplasty implants.

Maslaris Alexander, Spyrou Georgios, Schoeneberg Carsten, Citak Mustafa, Matziolis Georg

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

While re-revision total knee arthroplasty (ReRTKA) steadily increases, the ease and bone-sparing removal of RTKA implants is gaining more and more in importance. Biomechanical data suggest that cemented conical stems can be removed significantly easier than cylindrical stems. However, no clinical evidence exists supporting this observation. Aim of this study was to compare the revisability and need for osteotomy (OT) between removals of well-fixed cemented conical vs. cylindrical RTKA stems.

MATERIALS AND

METHODS

55 removals of well-fixed full-cemented RTKA stems (29 knees) performed between 2016 and 2018 were retrospectively analyzed. Main outcome variables were: bone loss, fractures, osteotomy incidence, surgery duration, early postoperative complications (EPC), hemoglobin drop and blood transfusion. SPSS was used for the statistical analysis.

RESULTS

44.8% were conical, 48.3% cylindrical, and 6.9% combined stem designs. Causes for re-revision were PJI (75.9%), malposition (17.2%) and persistent pain (6.9%). 10 stem removals (18.2%) required an OT (four femoral, six tibial): eight stems (14.5%) had cylindrical and two (3.6%) conical designs (P = 0.041). Fractures were noted solely in removals without OT (11.1% vs. 0%,). There was a tendency to more bone loss in cylindrical stem revisions (53.8% vs. 32%, P = 0.24). A longer overall surgery time was observed in revisions of cylindrical stems (+ 37 min, P = 0.05). There was higher hemoglobin drop and need for blood transfusion in revisions of cylindrical stems or after OT but without reaching statistical significance. The EPC rates were slightly higher in ReRTKA on cylindrical stems (P = 0.28).

CONCLUSION

Well-fixed cemented conical stems may be revision friendlier with less demands on OT and shorter overall surgery time than cemented cylindrical stems.

Для цитирования: Maslaris Alexander, Spyrou Georgios, Schoeneberg Carsten, Citak Mustafa, Matziolis Georg. Impact of stem profile on the revisability and the need for osteotomy in well-fixed cemented revision total knee arthroplasty implants.. Archives of orthopaedic and trauma surgery. 2022. DOI: 10.1007/s00402-022-04559-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.