MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2023.464610

Медицинская библиотека · Journal of chromatography. A · 2023

Development and validation of a bioanalytical method for the quantification of methotrexate from serum and capillary blood using volumetric absorptive microsampling (VAMS) and on-line solid phase extraction (SPE) LC-MS.

Opitz Patrick, Fobker Manfred, Fabian Jörg, Hempel Georg

СтатьяПеревод в очереди

Аннотация

High-dose methotrexate is part of the polychemotherapy protocols for the treatment of Acute lymphoblastic leukaemia (ALL) with therapeutic drug monitoring (TDM) to adjust leucovorin rescue. An immunoassay is commonly used to analyse serum samples collected via venous blood sampling. However, immunoassays cannot distinguish between the parent drug and its metabolites. Besides, the blood volume required by venous blood sampling is high. Therefore, the aim of this project was to develop a fast, simple, reliable and cost-efficient micro sampling bioanalytical method using capillary blood to minimize the harm of children and to analyse both methotrexate and its metabolites. To achieve this aim, a LC-MS method with on-line solid phase extraction (SPE) for the simultaneous detection of methotrexate and its metabolites from capillary blood using volumetric-absorptive-microsampling (VAMS) technology was developed and fully validated. Besides, the method was also validated and modified for serum samples to compare the results with the immunoassay. A single-quadrupole MS detector was used for detection. Through the use of on-line SPE technology, a lower limit of quantitation of 0.03 µM for MTX and 7-OH-MTX and of 0.05 µM for DAMPA from a 10 μL capillary blood sample was achieved. The accuracy is between 90.0 and 104% and the precision between 4.7 and 12% for methotrexate and its metabolites, respectively. Because of the cross reactivity of the immunoassay a cross-validation was not successful. Besides, a correlation factor of 0.46 for MTX between plasma and whole-blood was found. A fast, simple, reliable and cost-efficient extraction and analysis LC-MS method could be developed and validated, which is applicable in ambulatory and clinical care.

Для цитирования: Opitz Patrick, Fobker Manfred, Fabian Jörg, Hempel Georg. Development and validation of a bioanalytical method for the quantification of methotrexate from serum and capillary blood using volumetric absorptive microsampling (VAMS) and on-line solid phase extraction (SPE) LC-MS.. Journal of chromatography. A. 2023. DOI: 10.1016/j.chroma.2023.464610.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.