Balloon dilatation of the aortic valve after previous surgical valvotomy: immediate and follow up results.
Аннотация
OBJECTIVE
To evaluate the immediate and long-term results of transcatheter balloon dilatation of the aortic valve for restenosis after previous surgical valvotomy.
DESIGN
Prospective follow up by clinical examination and cross sectional Doppler echocardiography of all patients fulfilling the above criteria.
SETTING
Tertiary paediatric cardiology referral centre.
PATIENTS AND
METHODS
22 patients (18 male, 4 female)--median (range) age 157.5 (12-254) months--underwent 25 balloon dilatation procedures at a median of 72 (8-155) months after surgery. The median age at surgical valvotomy was 82.5 (0.5-230) months and the systolic gradient across the aortic valve immediately after surgery was 31 (0-49) mm Hg. The indication for dilatation was a Doppler derived peak instantaneous gradient of > 60 mm Hg with grade 2 or less aortic regurgitation. A single balloon was used, and the median balloon to annulus ratio was 1 (0.9-1).
RESULTS
After dilatation the catheter pullback gradient decreased acutely from 55 (35-75) to 30 (0-75) mm Hg (p < 0.01) and the Doppler gradient from 74 (52-92) to 40.5 (30-96) mm Hg (p < 0.01). In three patients who underwent a second dilatation of the aortic valve eight months after the first procedure, the pullback gradient decreased from 50 (50-60) to 15 (15-16) mm Hg. Aortic regurgitation grade increased from 1 (0-2) to 2 (1-3); only one patient had grade 3 regurgitation. Over a median follow up of 33 (2-67) months seven patients had aortic valve replacement for recurrent stenosis (six patients) or severe regurgitation (one patient with grade 3 regurgitation after dilatation, who had partial detachment of one of the valve leaflets). There was no significant difference for the pullback gradient (median of 19 v 32.5 mm Hg), Doppler gradient 24 hours after dilatation (33.5 v 50.5 mm Hg; p = 0.03), or the duration of follow up (27.5 v 18 months) between the 12 patients who did not require further dilatation or surgery and the 10 patients who did.
CONCLUSIONS
Balloon dilatation of the aortic valve is a safe and feasible option for palliation of restenosis after surgical valvotomy for congenital aortic valve stenosis. In many patients, however, stenosis progressed and a further intervention was required.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.