MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1536/ihj.17-742

Медицинская библиотека · International heart journal · 2018

A Patient-Specific Hollow Three-Dimensional Model for Simulating Percutaneous Occlusion of Patent Ductus Arteriosus.

Matsubara Daisuke, Kataoka Koichi, Takahashi Hironori, Minami Takaomi, Yamagata Takanori

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

Percutaneous catheter closure of patent ductus arteriosus (PDA) is difficult when the ductus is large and long or shows calcification. We created a patient-specific 3-dimensional (3D) model for PDA, with which we simulated device deployment, thereby selecting the device/size in a patient-by-patient manner. We assessed whether this 3D model is effective for catheter PDA closure.The 3D model was created in this institute, requiring 3 days and 90 US dollars. After its introduction, 7 consecutive patients (the study group) with severe PDA underwent closure with the aid of the 3D model. The control group consisted of 4 patients before 3D-model introduction, with all having severe PDA: the requirement of computed tomography was considered a criterion of severe or difficult-procedure-requiring PDA.In all study group patients, the devices/sizes could be pre-selected based on the simulation, whereas devices were changed during the procedure in 2 of 4 in the control group. In the study group, compared with the control group, the fluoroscopic (median 31 [interquartile range of 16-42] versus 39 [19-71] minutes, respectively) and total procedural times (median 107 [interquartile range 67-114] versus 124 [78-184] minutes, respectively) were shorter. A questionnaire confirmed the doctors' understanding of the procedure.This 3D model may be effective for percutaneous catheter closure of PDA. This may be especially true in cases of severe or difficult-procedure-requiring PDA.

Для цитирования: Matsubara Daisuke, Kataoka Koichi, Takahashi Hironori, Minami Takaomi, Yamagata Takanori. A Patient-Specific Hollow Three-Dimensional Model for Simulating Percutaneous Occlusion of Patent Ductus Arteriosus.. International heart journal. 2018. DOI: 10.1536/ihj.17-742.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.