MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acssensors.4c00240

Медицинская библиотека · ACS sensors · 2024

Integrating Photoelectrochemical Feature on a Hydrovoltaic Chip with High-Salinity Adaption as a Self-Powered Device for Formaldehyde Monitoring.

Zhang Zhechen, Guo Junli, Zhao Junjian, Tian Yuetong, Gao Zhida, Song Pei, Song Yan-Yan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Alternative energy sources are required due to the decline in fossil fuel resources. Therefore, devices that utilize hydrovoltaic technology and light energy have drawn widespread attention because they are emission-free and solar energy is inexhaustible. However, previous investigations mainly focused on accelerating the water evaporation rate at the electrode interface. Here, a cooperative photoelectrochemical effect on a hydrovoltaic chip is achieved using NH2-MIL-125-modified TiO2 nanotube arrays (NTs). This device demonstrated significantly improved evaporation-triggered electricity generation. Under LED illumination, the open-circuit voltage (VOC) of the NH2-MIL-125/TiO2NTs active layer of the hydrovoltaic chip was enhanced by 90.3% (up to 400.2 mV). Furthermore, the prepared hydrovoltaic chip showed good high-salinity tolerance, maintaining 74.6% of its performance even in 5 M NaCl. By introducing a Schiff-based reaction between the active layer and formaldehyde, a fully integrated flexible sensor was successfully fabricated for formaldehyde monitoring, and a low limit of detection of 5.2 × 10-9 M was achieved. This novel strategy for improving the performance of hydrovoltaic devices offers a completely new general approach to construct self-powered devices for point-of-care sensing.

Для цитирования: Zhang Zhechen, Guo Junli, Zhao Junjian, Tian Yuetong, Gao Zhida, Song Pei, Song Yan-Yan. Integrating Photoelectrochemical Feature on a Hydrovoltaic Chip with High-Salinity Adaption as a Self-Powered Device for Formaldehyde Monitoring.. ACS sensors. 2024. DOI: 10.1021/acssensors.4c00240.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.