MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.envres.2024.118236

Медицинская библиотека · Environmental research · 2024

Effects of 90 dB pure tone exposure on auditory and cardio-cerebral system functions in macaque monkeys.

Zhi Weijia, Li Ying, Wang Yuchen, Zou Yong, Wang Haoyu, Xu Xinping, Ma Lizhen, Ren Yanling, Qiu Yefeng, Hu Xiangjun, Wang Lifeng

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Excessive noise exposure presents significant health risks to humans, affecting not just the auditory system but also the cardiovascular and central nervous systems. This study focused on three male macaque monkeys as subjects. 90 dB sound pressure level (SPL) pure tone exposure (frequency: 500Hz, repetition rate: 40Hz, 1 min per day, continuously exposed for 5 days) was administered. Assessments were performed before exposure, during exposure, immediately after exposure, and at 7-, 14-, and 28-days post-exposure, employing auditory brainstem response (ABR) tests, electrocardiograms (ECG), and electroencephalograms (EEG). The study found that the average threshold for the Ⅴ wave in the right ear increased by around 30 dB SPL right after exposure (P < 0.01) compared to pre-exposure. This elevation returned to normal within 7 days. The ECG results indicated that one of the macaque monkeys exhibited an RS-type QRS wave, and inverted T waves from immediately after exposure to 14 days, which normalized at 28 days. The other two monkeys showed no significant changes in their ECG parameters. Changes in EEG parameters demonstrated that main brain regions exhibited significant activation at 40Hz during noise exposure. After noise exposure, the power spectral density (PSD) in main brain regions, particularly those represented by the temporal lobe, exhibited a decreasing trend across all frequency bands, with no clear recovery over time. In summary, exposure to 90 dB SPL noise results in impaired auditory systems, aberrant brain functionality, and abnormal electrocardiographic indicators, albeit with individual variations. It has implications for establishing noise protection standards, although the precise mechanisms require further exploration by integrating pathological and behavioral indicators.

Для цитирования: Zhi Weijia, Li Ying, Wang Yuchen, Zou Yong, Wang Haoyu, Xu Xinping, Ma Lizhen, Ren Yanling, Qiu Yefeng, Hu Xiangjun, Wang Lifeng. Effects of 90 dB pure tone exposure on auditory and cardio-cerebral system functions in macaque monkeys.. Environmental research. 2024. DOI: 10.1016/j.envres.2024.118236.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.