MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s1047951118001257

Медицинская библиотека · Cardiology in the young · 2018

Effects of reducing frame rate from 7.5 to 4 frames per second on radiation exposure in transcatheter atrial septal defect closure.

Boudjemline Younes

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The aim of this study was to evaluate the reduction of frame rate from 7.5 to 4 frames per second on radiation exposure and to provide new standards of radiation exposure.

BACKGROUND

Frame rate is a large contributor to radiation exposure. The use of 4 frames per second for closure of atrial septal defects has been reported not to affect the level of radiation exposure.

METHODS

We retrospectively reviewed radiation data from all patients referred to our catheterisation laboratory for closure of an atrial septal defect between January, 2015 and June, 2017. Fluoroscopic time, dose area product (μGy.m2), and total air kerma (mGy) were collected. These values were compared according to the frame rate used for closure of atrial septal defects.

RESULTS

A total of 49 atrial septal defects were closed using 7.5 frames per second and 85 using 4 frames per second. Baseline characteristics were similar in both groups. Procedural success was similar in both groups (100 versus 98.8%). Median total air kerma and dose area product were statistically lower in the 4 frames per second group (4 versus 1.3 mGy [p=0.00012]), 43.7 versus 13.1 μGy.m2 [p0.05).

CONCLUSION

Reduction of frame rate allows reducing significantly the radiation exposure while maintaining excellent clinical results in transcatheter closure of atrial septal defects. We recommend implementing this little change in every laboratory in order to achieve drastic reduction of radiation exposure to the patients and laboratory personnel.

Для цитирования: Boudjemline Younes. Effects of reducing frame rate from 7.5 to 4 frames per second on radiation exposure in transcatheter atrial septal defect closure.. Cardiology in the young. 2018. DOI: 10.1017/s1047951118001257.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.