DOI 10.1097/pcc.0000000000000055
Changes in cerebral oxygen saturation correlate with S100B in infants undergoing cardiac surgery with cardiopulmonary bypass.
Аннотация
OBJECTIVES
The relationship of cerebral saturation measured by near-infrared spectroscopy with serum biomarker of brain injury S100B was investigated in infants undergoing cardiac surgery with cardiopulmonary bypass.
DESIGN
Prospective cohort study.
SETTING
Single-center children's hospital.
PATIENTS: Forty infants between 1 and 12 months old weighing greater than or equal to 4 kg with congenital heart disease undergoing cardiac surgery with cardiopulmonary bypass were enrolled.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN
RESULTS
Serum S100B was measured at eight time points over 72 hours using enzyme-linked immunosorbent assay. Physiologic data including arterial, cerebral, and somatic regional oxygen saturations measured by near-infrared spectroscopy were synchronously recorded at 1-minute intervals from anesthesia induction through 72 postoperative hours. The arterial-cerebral oxygen saturation difference was calculated as the difference between arterial saturation and cerebral regional saturation. Thirty-eight patients, 5.4 ± 2.5 months old, were included in the analysis; two were excluded due to the use of postoperative extracorporeal membrane oxygenation. Seventeen patients (44.7%) had preoperative cyanosis. S100B increased during cardiopulmonary bypass in all patients, from a median preoperative baseline of mean ± SE: 0.055 ± 0.038 to a peak of 0.610 ± 0.038 ng/mL, p less than 0.0001. Patients without preoperative cyanosis had a higher S100B peak at the end of cardiopulmonary bypass. Although the absolute cerebral regional saturation on cardiopulmonary bypass was not associated with S100B elevation, patients who had arterial-cerebral oxygen saturation difference greater than 50 at any time during cardiopulmonary bypass had a higher S100B peak (mean ± SE: 1.053 ± 0.080 vs 0.504 ± 0.039 ng/mL; p < 0.0001).
CONCLUSIONS
A wide cerebral arteriovenous difference measured by near-infrared spectroscopy during cardiopulmonary bypass is associated with increased serum S100B in the perioperative period and may be a modifiable risk factor for neurological injury.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.