MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/1010-7940(94)90072-8

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 1994

Mechanical circulatory support in children.

Scheinin S A, Radovancevic B, Parnis S M, Ott D A, Bricker J T, Towbin J A, Abou-Awdi N L, Frazier O H

СтатьяПеревод в очереди

Аннотация

Nine children (aged 1.2-15 years) have been treated with mechanical circulatory support devices at our institution. Indications for treatment were acute cardiac allograft rejection (n = 4), postcardiotomy cardiogenic shock (n = 4), and bridge to cardiac transplantation (n = 1). Eight patients required left ventricular support, and one required biventricular support. A BioMedicus centrifugal pump was used in eight patients, and a Hemopump intra-aortic axial flow device was used in one patient. In two patients, an intra-aortic balloon pump was in place at the time that circulatory support was instituted. Mechanical support time ranged from 2 to 139 h, and the average flow index was 2.31 l/min per m2. Three patients required hemodialysis during support, and one patient required re-exploration because of mediastinal hemorrhage. Recovery of native ventricular function was assessed by transthoracic or transesophageal echocardiography, and weaning from the device was achieved by gradually decreasing pump flow in increments of 0.1 to 0.5 l/min. Seven patients were successfully weaned from support. Two hospital deaths occurred after circulatory support had been discontinued: one patient died of respiratory failure and the other of gram-negative pneumonia and sepsis. The five surviving patients experienced no significant complications, and their hemodynamic indices were normal at the time of discharge. At a mean follow-up of 28.8 months, these patients are leading active unrestricted lives, with no long-term device-related sequelae. Based on this experience, mechanical circulatory support is feasible in children who experience profound circulatory failure from a variety of causes.

Для цитирования: Scheinin S A, Radovancevic B, Parnis S M, Ott D A, Bricker J T, Towbin J A, Abou-Awdi N L, Frazier O H. Mechanical circulatory support in children.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 1994. DOI: 10.1016/1010-7940(94)90072-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.