Plasma D-dimer safely reduces unnecessary CT scans obtained in the evaluation of pediatric head trauma.

Langness Simone, Ward Erin, Halbach Jonathan, Lizardo Radhames, Davenport Katherine, Bickler Stephen, Kling Karen, Thangarajah Hari, Grabowski Julia, Fairbanks Timothy

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: Serum D-dimer has been proposed as a biomarker to aid in the diagnosis of pediatric traumatic brain injury (TBI). We investigated the accuracy of D-dimer in predicting the absence of TBI and evaluated the degree by which D-dimer could limit unnecessary computed tomography scans of the head (CTH).

METHODS

Retrospective review of patients with suspected TBI from 2011 to 2013 who underwent evaluation with CTH and quantitative D-dimer. D-dimer levels were compared among patients with clinically-important TBI (ciTBI), TBI, isolated skull fracture and no injury.

RESULTS

Of the 663 patients evaluated for suspected TBI, ciTBI was identified in 116 (17.5%), TBI in 77 (11.6%), skull fracture in 61 (9.2%) and no head injury in 409 (61.7%). Patients with no head injury had significantly lower D-dimer values (1531±1791pg/μL) compared to those with skull fracture, TBI and ciTBI (2504±1769, 2870±1633 and 4059±1287pg/μL, respectively, p<0.005). Using a D-dimer value <750pg/μL as a negative screen, no ciTBIs would be missed and 209 CTHs avoided (39.7% of total).

CONCLUSION

Low plasma D-dimer predicts the absence of ciTBI for pediatric patient with suspected TBI. Incorporating D-dimer into current diagnostic algorithms may significantly limit the number of unnecessary CTHs performed in this population.

TYPE OF STUDY: Study of diagnostic test.

LEVEL OF EVIDENCE: I.

Для цитирования: Langness Simone, Ward Erin, Halbach Jonathan, Lizardo Radhames, Davenport Katherine, Bickler Stephen, Kling Karen, Thangarajah Hari, Grabowski Julia, Fairbanks Timothy. Plasma D-dimer safely reduces unnecessary CT scans obtained in the evaluation of pediatric head trauma.. Journal of pediatric surgery. 2017. DOI: 10.1016/j.jpedsurg.2017.08.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.