MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmbbm.2013.05.002

Медицинская библиотека · Journal of the mechanical behavior of biomedical materials · 2013

Mechanical and tribological behavior of silicon nitride and silicon carbon nitride coatings for total joint replacements.

Pettersson M, Tkachenko S, Schmidt S, Berlind T, Jacobson S, Hultman L, Engqvist H, Persson C

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Total joint replacements currently have relatively high success rates at 10-15 years; however, increasing ageing and an active population places higher demands on the longevity of the implants. A wear resistant configuration with wear particles that resorb in vivo can potentially increase the lifetime of an implant. In this study, silicon nitride (SixNy) and silicon carbon nitride (SixCyNz) coatings were produced for this purpose using reactive high power impulse magnetron sputtering (HiPIMS). The coatings are intended for hard bearing surfaces on implants. Hardness and elastic modulus of the coatings were evaluated by nanoindentation, cohesive, and adhesive properties were assessed by micro-scratching and the tribological performance was investigated in a ball-on-disc setup run in a serum solution. The majority of the SixNy coatings showed a hardness close to that of sintered silicon nitride (~18 GPa), and an elastic modulus close to that of cobalt chromium (~200 GPa). Furthermore, all except one of the SixNy coatings offered a wear resistance similar to that of bulk silicon nitride and significantly higher than that of cobalt chromium. In contrast, the SixCyNz coatings did not show as high level of wear resistance.

Для цитирования: Pettersson M, Tkachenko S, Schmidt S, Berlind T, Jacobson S, Hultman L, Engqvist H, Persson C. Mechanical and tribological behavior of silicon nitride and silicon carbon nitride coatings for total joint replacements.. Journal of the mechanical behavior of biomedical materials. 2013. DOI: 10.1016/j.jmbbm.2013.05.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.