MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2018.03.059

Медицинская библиотека · International journal of cardiology · 2018

Is the new Occlutech duct occluder an appropriate device for transcatheter closure of patent ductus arteriosus?

Godart François, Houeijeh Ali, Domanski Olivia, Guillaume Marie-Paule, Brard Mélanie, Lucron Hugues

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

AIM: To describe our initial experience with the Occlutech Duct Occluder (ODO) for percutaneous closure of patent ductus arteriosus (PDA).

METHODS

Retrospective review of patients undergoing transcatheter PDA closure with the ODO in 2 academic centers.

RESULTS

From April 2013 to September 2017, 42 patients underwent PDA closure. Median age at implantation was 34 months (range 4 months-68 years) and median weight was 12 kg (range 4.1-57 kg). Ducts were Krichenko type A duct (n = 34), type E (n = 6), and type C (n = 2). The mean duct diameter was 3.76 mm (range 1.69 to 9.95 mm, median 3.1 mm). Implantation succeeded in all. There was neither device embolization nor hemolysis. At device release, immediate angiogram showed a small residual shunt in 54.7%. During follow-up, Doppler echocardiography demonstrated 71% of full occlusion at day one, rising to 95% at one month and 100% at one year and half after implantation. The mean maximal systolic pressure gradient in left pulmonary artery was 4.2 ± 4.3 mm and across the distal aortic arch 5.4 ± 4.7 mm Hg. No patient had any significant stenosis with clinical relevance.

CONCLUSIONS

ODO is safe and effective in transcatheter closure of PDA including relatively large sized ducts. The results are satisfactory with a high level of full occlusion and a low rate of complications. Further evaluation with larger studies and longer follow-up will be required to confirm these preliminary good results.

Для цитирования: Godart François, Houeijeh Ali, Domanski Olivia, Guillaume Marie-Paule, Brard Mélanie, Lucron Hugues. Is the new Occlutech duct occluder an appropriate device for transcatheter closure of patent ductus arteriosus?. International journal of cardiology. 2018. DOI: 10.1016/j.ijcard.2018.03.059.