MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12936-019-3027-0

Медицинская библиотека · Malaria journal · 2019

High-throughput malaria serosurveillance using a one-step multiplex bead assay.

Rogier Eric, van den Hoogen Lotus, Herman Camelia, Gurrala Kevin, Joseph Vena, Stresman Gillian, Presume Jacquelin, Romilus Ithamare, Mondelus Gina, Elisme Tamara, Ashton Ruth, Chang Michelle, Lemoine Jean F, Druetz Thomas, Eisele Thomas P, Existe Alexandre, Boncy Jacques, Drakeley Chris, Udhayakumar Venkatachalam

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Serological data indicating the presence and level of antibodies against infectious disease antigens provides indicators of exposure and transmission patterns in a population. Laboratory testing for large-scale serosurveys is often hindered by time-consuming immunoassays that employ multiple tandem steps. Some nations have recently begun using malaria serosurveillance data to make inferences about the malaria exposure in their populations, and serosurveys have grown increasingly larger as more accurate estimates are desired. Presented here is a novel approach of antibody detection using bead-based immunoassay that involves incubating all assay reagents concurrently overnight.

RESULTS

A serosurvey in was performed in Haiti in early 2017 with both sera (n = 712) and dried blood spots (DBS, n = 796) collected for the same participants. The Luminex® multiplex bead-based assay (MBA) was used to detect total IgG against 8 malaria antigens: PfMSP1, PvMSP1, PmMSP1, PfCSP, PfAMA1, PfLSA1, PfGLURP-R0, PfHRP2. All sera and DBS samples were assayed by MBA using a standard immunoassay protocol with multiple steps, as well a protocol where sample and all reagents were incubated together overnight-termed here the OneStep assay. When compared to a standard multi-step assay, this OneStep assay amplified the assay signal for IgG detection for all 8 malaria antigens. The greatest increases in assay signal were seen at the low- and mid-range IgG titers and were indicative of an enhancement in the analyte detection, not simply an increase in the background signal of the assay. Seroprevalence estimates were generally similar for this sample Haitian population for all antigens regardless of serum or DBS sample type or assay protocol used.

CONCLUSIONS

When using the MBA for IgG detection, overnight incubation for the test sample and all assay reagents greatly minimized hands-on time for laboratory staff. Enhanced IgG signal was observed with the OneStep assay for all 8 malaria antigens employed in this study, and seroprevalence estimates for this sample population were similar regardless of assay protocol used. This overnight incubation protocol has the potential to be deployed for large-scale malaria serosurveys for the high-throughput and timely collection of antibody data, particularly for malaria seroprevalence estimates.

Для цитирования: Rogier Eric, van den Hoogen Lotus, Herman Camelia, Gurrala Kevin, Joseph Vena, Stresman Gillian, Presume Jacquelin, Romilus Ithamare, Mondelus Gina, Elisme Tamara, Ashton Ruth, Chang Michelle, Lemoine Jean F, Druetz Thomas, Eisele Thomas P, Existe Alexandre, Boncy Jacques, Drakeley Chris, Udhayakumar Venkatachalam. High-throughput malaria serosurveillance using a one-step multiplex bead assay.. Malaria journal. 2019. DOI: 10.1186/s12936-019-3027-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.