MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjo-2025-328883

Медицинская библиотека · The British journal of ophthalmology · 2026

Nomogram for predicting implant exposure risk following enucleation or evisceration with vicryl-meshed hydroxyapatite implants.

Wang Minghui, Heindl Ludwig M, Salim Omar Rafea Salim, Guo Yongwei, Niederau Constantin, Fan Wanlin, Rokohl Alexander Christopher

СтатьяПеревод в очереди

Аннотация

AIMS: To develop and validate a nomogram predicting the risk of implant exposure in patients receiving vicryl-meshed hydroxyapatite (HA) orbital implants following enucleation or evisceration.

METHODS

This is a retrospective study at the University Hospital of Cologne, which included 336 patients with primary vicryl-meshed HA implants. Univariate and multivariate logistic regression analyses identified independent risk factors for implant exposure. A nomogram was constructed, and its performance was evaluated using the area under the receiver operating characteristic curve (AUC), calibration curves and decision curve analysis (DCA).

RESULTS

Independent risk factors for implant exposure included previous ocular trauma (OR 2.08; 95% CI 1.01 to 4.31; p=0.048), diabetes mellitus (OR 4.17; 95% CI 1.81 to 9.63; p<0.001), autoimmune disease (OR 4.69; 95% CI 1.15 to 19.09; p=0.031), chemotherapy or radiotherapy (OR 4.25; 95% CI 1.09 to 16.58; p=0.037), hormone therapy (OR 2.35; 95% CI 1.04 to 5.30; p=0.039) and previous ocular surgery (OR 2.65; 95% CI 1.33 to 5.27; p=0.005). The nomogram demonstrated moderate discriminative ability (AUC 0.725 for both training and validation sets) and good calibration, with potential clinical utility supported by DCA.

CONCLUSION

This nomogram provides a practical tool for identifying patients at higher risk of exposure following vicryl-meshed HA implantation and may inform individualised preventive strategies. As this is a single-centre study, its applicability is currently limited to this implant type and wrapping technique, and external validation in other centres and populations is needed to confirm its generalisability.

Для цитирования: Wang Minghui, Heindl Ludwig M, Salim Omar Rafea Salim, Guo Yongwei, Niederau Constantin, Fan Wanlin, Rokohl Alexander Christopher. Nomogram for predicting implant exposure risk following enucleation or evisceration with vicryl-meshed hydroxyapatite implants.. The British journal of ophthalmology. 2026. DOI: 10.1136/bjo-2025-328883.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.