MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/echo.13715

Медицинская библиотека · Echocardiography (Mount Kisco, N.Y.) · 2017

Preliminary study of the application of transthoracic echocardiography-guided three-dimensional printing for the assessment of structural heart disease.

Zhu Yanbo, Liu Jianshi, Wang Lianqun, Guan Xin, Luo Yongjuan, Geng Jie, Geng Qingguo, Lin Yunjia, Zhang Lixia, Li Xixue, Lu Yaping

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To investigate the feasibility and diagnostic value of a preoperative transthoracic echocardiography-guided three-dimensional printed model (TTE-guided 3DPM) for the assessment of structural heart disease (SHD).

METHODS

Fourty-four patients underwent cardiac surgery at Tianjin Chest Hospital. The patients were preoperatively assessed using TTE-guided 3DPM, which was compared to conventional three-dimensional transthoracic echocardiography (3DTTE) along with direct intraoperative findings, which were considered the "gold standard." Twelve patients had SHD, including four with mitral prolapse, two with partial endocardial cushion defects, two with secondary atrial septal defects, two with rheumatic mitral stenosis, one with tetralogy of Fallot, and one with a ventricular septal defect (VSD). Thirty-two patients who did not have SHDs were designated as the negative control group.

RESULTS

The sensitivity and specificity of the TTE-guided 3DPM were greater than or equal to those of the 3DTTE. The P-value of the McNemar test of 3DTTE was >.05, which indicates that the difference was not statistically significant (Kappa = 0.745, P < .001). The P-value of the McNemar test of TTE-guided 3DPM was >.05, which indicates that the difference was not statistically significant (Kappa = 0.955, P < .001). A comparison of 3DTTE and TTE-guided 3DPM resulted in a P-value >.05, which indicates that the difference was not statistically significant (Kappa = 0.879, P < .001). TTE-guided 3DPM displayed the 3D structure of SHDs and cardiac lesions clearly and was consistent with the intra-operative findings.

CONCLUSION

Transthoracic echocardiography-guided three-dimensional printed model (TTE-guided 3DPM) provides essential information for preoperative evaluation and decision making for patients with SHDs.

Для цитирования: Zhu Yanbo, Liu Jianshi, Wang Lianqun, Guan Xin, Luo Yongjuan, Geng Jie, Geng Qingguo, Lin Yunjia, Zhang Lixia, Li Xixue, Lu Yaping. Preliminary study of the application of transthoracic echocardiography-guided three-dimensional printing for the assessment of structural heart disease.. Echocardiography (Mount Kisco, N.Y.). 2017. DOI: 10.1111/echo.13715.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.