MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.15087

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2024

Caught in the Act: A Detailed Analysis of Cardiac Event Monitoring in a Cohort of Pediatric and ACHD Patients.

Srivatsav Ashwin, Thompson Zachery J, Bruno Michael A, Stephens Sara B, Gutierrez Maria Elena, Miyake Christina Y, Morris Shaine A, Dan Pham Tam, Valdes Santiago O, Kim Jeffrey J, Howard Taylor S

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Event monitors are being increasingly used in pediatric and adult congenital heart disease (ACHD) patients for arrhythmia evaluation. Data on their diagnostic yield are limited.

OBJECTIVES

To evaluate the diagnostic yield of event monitors, patient characteristics associated with critical events, and clinical response to events.

METHODS

We retrospectively assessed event monitors prescribed to patients at our institution's Heart Center from 2017 to 2020. Thirty-day event monitor tracings were reviewed by an electrophysiologist (EP) to identify critical events defined as supraventricular tachycardia (SVT, re-entrant, atrial tachycardia, atrial flutter, and atrial fibrillation), ventricular tachycardia (VT), atrioventricular block, and pauses greater than 3 s. Patient characteristics and treatment data were collected. Characteristics associated with events were assessed using multivariable logistic regression. Trends in monitor prescription over time, diagnostic yield, and clinical response to events were analyzed.

RESULTS

204/2330 (8.8%) event monitors had EP-confirmed critical events. Critical events included SVT (51.5%), VT (38.5%), atrioventricular block (4%), and pauses (6%). 129/198 (65%) patients with critical events underwent treatment. Event monitoring usage increased by 52% between 2017 and 2020 (p < 0.0001). Complex CHD (OR 2.1, 95% CI 1.3-3.4, p = 0.004), cardiomyopathy (OR 2.9, 95% CI 1.5-4.8, p < 0.001), and EP-ordered monitors (OR 1.6, 95% CI 1.2-2.1, p = 0.001) were more highly associated with critical events.

CONCLUSION

Event monitor use is common, and critical events were captured in 8.8% of patients. The majority of patients with critical events underwent treatment. Factors associated with critical events include EPs as ordering providers, complex CHD, and cardiomyopathy.

Для цитирования: Srivatsav Ashwin, Thompson Zachery J, Bruno Michael A, Stephens Sara B, Gutierrez Maria Elena, Miyake Christina Y, Morris Shaine A, Dan Pham Tam, Valdes Santiago O, Kim Jeffrey J, Howard Taylor S. Caught in the Act: A Detailed Analysis of Cardiac Event Monitoring in a Cohort of Pediatric and ACHD Patients.. Pacing and clinical electrophysiology : PACE. 2024. DOI: 10.1111/pace.15087.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.