Peiro Jose L, Duru Soner, Fernandez-Tome Blanca, Peiro Lucas, Encinas Jose L, Sanchez-Margallo Francisco M, Oria Marc
Аннотация
BACKGROUND: Congenital obstructive hydrocephalus generates progressive irreversible fetal brain damage by ventricular enlargement and incremental brain tissue compression that leads to maldevelopment and poor clinical outcomes. Intrauterine treatments such as ventriculo-amniotic shunting have been unsuccessfully tried in the eighties.
OBJECTIVE: To assess if prenatal endoscopic third ventriculostomy (ETV) is feasible in a large animal model and optimize this technique for ventricular decompression and potential arrest of fetal brain damage in fetal lambs.
METHODS: We generated hydrocephalus in 50 fetal lambs by injecting a polymeric agent into the cisterna magna at midgestation (E85). Subsequently, 3 weeks later (E105), fetal ETV was performed using a small rigid fetoscope. The endoscopy entry point was located anterior to the coronal suture, 7 mm from the midline.
RESULTS: We obtained clear visualization of the enlarged lateral ventricles by endoscopy in the hydrocephalic fetal lambs. The floor of the third ventricle was bluntly perforated and passed with the scope for a successful ETV. Total success was achieved in 32/50 cases (64%). Causes of failure were blurred vision or third ventricle obliteration by BioGlue in 10/50 (20%) cases, anatomic misdirection of the endoscope in 5 (10%) cases, 2 cases of very narrow foramen of Monro, and 1 case of choroid plexus bleeding. If we exclude the cases artificially blocked by the polymer, we had a successful performance of prenatal-ETV in 80% (32/40) of hydrocephalic fetuses.
CONCLUSION: Despite the inherent difficulties arising from ovine brain anatomy, this study shows that innovative fetal ETV is technically feasible in hydrocephalic fetal lambs.
OBJECTIVE: To assess if prenatal endoscopic third ventriculostomy (ETV) is feasible in a large animal model and optimize this technique for ventricular decompression and potential arrest of fetal brain damage in fetal lambs.
METHODS: We generated hydrocephalus in 50 fetal lambs by injecting a polymeric agent into the cisterna magna at midgestation (E85). Subsequently, 3 weeks later (E105), fetal ETV was performed using a small rigid fetoscope. The endoscopy entry point was located anterior to the coronal suture, 7 mm from the midline.
RESULTS: We obtained clear visualization of the enlarged lateral ventricles by endoscopy in the hydrocephalic fetal lambs. The floor of the third ventricle was bluntly perforated and passed with the scope for a successful ETV. Total success was achieved in 32/50 cases (64%). Causes of failure were blurred vision or third ventricle obliteration by BioGlue in 10/50 (20%) cases, anatomic misdirection of the endoscope in 5 (10%) cases, 2 cases of very narrow foramen of Monro, and 1 case of choroid plexus bleeding. If we exclude the cases artificially blocked by the polymer, we had a successful performance of prenatal-ETV in 80% (32/40) of hydrocephalic fetuses.
CONCLUSION: Despite the inherent difficulties arising from ovine brain anatomy, this study shows that innovative fetal ETV is technically feasible in hydrocephalic fetal lambs.