MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7171/jbt.12-2304-001

Медицинская библиотека · Journal of biomolecular techniques : JBT · 2012

A mass spectrometric study for comparative analysis and evaluation of metabolite recovery from plasma by various solvent systems.

Dutta Anwesha, Shetty Premalatha, Bhat Smitha, Ramachandra Yeshaswini, Hegde Shrinidhi

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A solvent system that extracts a maximum number of metabolites belonging to diverse chemical classes from complex biofluids, such as plasma, may offer useful inputs to understand the metabolic and physiological state of an individual. The present study compared seven solvent systems for extraction of metabolites from plasma. The extracts were analyzed by mass spectrometry (MS) and MS/MS (MS2) using a quadrupole time-of-flight liquid chromatography/MS system in positive and negative modes of ionization. Metabolites with molecular mass below 400 were identified using Human Metabolome Database MS2 and MS search interfaces. The acetone/isopropanol (2:1) system yielded promising results in positive ionization mode, as the maximum number of MS and MS2 features was detected in the extract. It was found to be superior in extraction of various classes of metabolites, especially organic acids, nucleosides and nucleoside derivatives, and heterocyclic molecules. Glycerophosphocholines in the mass range of 400-700 were found to be efficiently extracted by the methanol/chloroform/water (8:1:1) system. In negative mode as well, the maximum number of MS2 features was detected in methanol/chloroform/water and acetone/isopropanol extracts. The fingerprints of molecular features obtained in the negative and positive modes differed from each other to a significant extent.

Для цитирования: Dutta Anwesha, Shetty Premalatha, Bhat Smitha, Ramachandra Yeshaswini, Hegde Shrinidhi. A mass spectrometric study for comparative analysis and evaluation of metabolite recovery from plasma by various solvent systems.. Journal of biomolecular techniques : JBT. 2012. DOI: 10.7171/jbt.12-2304-001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.