OBJECTIVES

Classical, longer olfactory tests are associated with difficulties in everyday practice. The aim of this study was to investigate the clinical utility of the Q-Sticks test within the context of a multicenter study.

METHODS

A total of 333 subjects, aged between 12 and 88 years, completed a 3-item Q-Sticks test and a longer Sniffin' Sticks identification test. We analyzed the sensitivity and specificity of the test results for different cutoffs for anosmia and hyposmia.

RESULTS

Our study showed that the test can be used on subjects aged 12 years and older, regardless of their sex. The data indicated a test sensitivity and specificity of 91.8 and 92%, respectively, with a score of 2 taken as a cutoff for olfactory dysfunction. Conversely, normal olfactory function can be declared with high probability with a score of 3 in the Q-Sticks test.

CONCLUSION

We reconfirmed that the Q-Sticks test is a good screening tool for everyday medical practice and in laboratory settings, although it has to be kept in mind that the test can produce false-negative results at a score of 3. The test was relatively sensitive to anosmia and differences between normosmic and hyposmic/anosmic patients.

Для цитирования: Sorokowska Agnieszka, Oleszkiewicz Anna, Minovi Amir, Konnerth Claus Günther, Hummel Thomas. Fast Screening of Olfactory Function Using the Q-Sticks Test.. ORL; journal for oto-rhino-laryngology and its related specialties. 2019. DOI: 10.1159/000500559.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.