MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.annemergmed.2014.08.043

Медицинская библиотека · Annals of emergency medicine · 2014

Accuracy of ultrasonography for determining successful realignment of pediatric forearm fractures.

Dubrovsky Alexander Sasha, Kempinska Anna, Bank Ilana, Mok Elise

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

OBJECTIVE

The primary objective of this study is to assess the accuracy of point-of-care ultrasonography compared with blinded orthopedic assessment of fluoroscopy in determining successful realignment of pediatric forearm fractures. The secondary objective is to determine the rate of agreement of ultrasonography and fluoroscopy in real-time by the treating physician.

METHODS

A cross-sectional study was conducted in children younger than 18 years and presenting to an academic emergency department with forearm fractures requiring realignment of a single bone. Physicians performed closed reductions with ultrasonographic assessment of realignment until the best possible reduction was achieved. Fluoroscopy was then immediately performed and images were saved. A positive test result was defined as an inadequately reduced fracture on fluoroscopy by a blinded pediatric orthopedic surgeon (reference standard) and on ultrasonography (index test) and fluoroscopy in real-time by the treating physician.

RESULTS

One hundred patients were enrolled (median age 12.1 years; 74% male patients); the radius was involved in 98%, with 27% involving the growth plate. The sensitivity, specificity, positive predictive value, and negative predictive value were 50% (95% confidence interval [CI] 15.4% to 84.6%), 89.1% (95% CI 82.8% to 95.5%), 28.6% (95% CI 4.9% to 52.2%), and 95.3% (95% CI 90.9% to 99.8%), respectively. The treating physicians' agreement rate of the real-time images was 98%.

CONCLUSION

Point-of-care ultrasonography can help emergency physicians determine when pediatric forearm fractures have been adequately realigned, but inadequate reductions should be confirmed by other imaging modalities.

Для цитирования: Dubrovsky Alexander Sasha, Kempinska Anna, Bank Ilana, Mok Elise. Accuracy of ultrasonography for determining successful realignment of pediatric forearm fractures.. Annals of emergency medicine. 2014. DOI: 10.1016/j.annemergmed.2014.08.043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.