MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/vbz.2019.2547

Медицинская библиотека · Vector borne and zoonotic diseases (Larchmont, N.Y.) · 2019

The Lyme Disease Polymerase Chain Reaction Test Has Low Sensitivity.

Nigrovic Lise E, Lewander David P, Balamuth Fran, Neville Desiree N, Levas Michael N, Bennett Jonathan E, Garro Aris

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Background

The Lyme PCR is a direct detection test, but has not been rigorously evaluated in children undergoing evaluation for acute Lyme disease.

Methods

We performed a six-center prospective cohort study of children aged 1 to 21 years undergoing acute evaluation for Lyme disease. For this planned secondary analysis, we limited our cohort to children undergoing evaluation for Lyme disease who had any Lyme PCR test obtained by a treating clinician (blood, synovial fluid, or cerebrospinal fluid). We defined a case of Lyme disease with a positive two-tier Lyme disease serology: a positive or equivocal enzyme immunoassay followed by a positive supplemental immunoblot interpreted using standard criteria. We report the test characteristics of Lyme PCR for the diagnosis of Lyme disease.

Results

We identified 124 children of whom 54 (43.5%) had Lyme disease. Overall, 23 had a positive PCR test (sensitivity 41.8%; 95% confidence interval [CI] 29.7-55.0; specificity 100%, 95% CI: 94.2-100). All children with a positive Lyme PCR also had a positive two-tiered Lyme disease serology.

Conclusions

The Lyme disease PCR test did not improve the diagnosis of children undergoing evaluation for acute Lyme disease. Given the additional costs of this low utility test, clinicians should not order Lyme PCR testing in the acute care setting.

Для цитирования: Nigrovic Lise E, Lewander David P, Balamuth Fran, Neville Desiree N, Levas Michael N, Bennett Jonathan E, Garro Aris. The Lyme Disease Polymerase Chain Reaction Test Has Low Sensitivity.. Vector borne and zoonotic diseases (Larchmont, N.Y.). 2019. DOI: 10.1089/vbz.2019.2547.