A novel method for transcranial Doppler microembolic signal monitoring at the vertebrobasilar junction in vertebral artery dissection patients.

Yamaoka Y, Ichikawa Y, Kimura T, Sameshima T, Ochiai C, Morita A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Vertebral artery dissection (VAD) is one of the most important etiologies in young stroke patients. VAD causes ischemic stroke by embolism and transcranial Doppler (TCD) monitoring can detect microemboli originating from the dissection point as high intensity transient signals (HITS). We developed a simple but novel method of TCD monitoring at the vertebrobasilar junction in VAD patients.

METHODS

We placed a Welder TCD headband upside down on the patient's head and rotated it by 90°. Then we fixed a pulsed-wave 2-MHz TCD probe to the headband and put it on the suboccipital paramedian area of the patient. With a patient in the lateral decubitus position, the vertebrobasilar junction was identified at a depth of approximately 80 mm.

RESULTS

We examined 11 patients with VAD and detected HITS in 2 patients (18%). In 1 patient HITS disappeared after heparinization, and in the other patient HITS disappeared after treatment with aspirin. All of 9 HITS-negative patients and 1 of 2 HITS-positive patients experienced no ischemic recurrence during hospitalization.

CONCLUSION

We successfully detected HITS at the vertebrobasilar junction in VAD patients, which may lead not only to an appropriate choice of antithrombotic drugs but also to individual evaluation of early risk of ischemic recurrence.

Для цитирования: Yamaoka Y, Ichikawa Y, Kimura T, Sameshima T, Ochiai C, Morita A. A novel method for transcranial Doppler microembolic signal monitoring at the vertebrobasilar junction in vertebral artery dissection patients.. Journal of neuroimaging : official journal of the American Society of Neuroimaging. 2012. DOI: 10.1111/j.1552-6569.2012.00749.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.