PURPOSE: To explore the role of Joshi's external stabilisation system fixator in correcting cases of clubfoot peculiar to India, we studied cases of neglected clubfoot, dropout cases of plaster-of-paris cast treatment, or failed surgical procedures that had been followed for a minimum period of 2 years.

METHODS

26 children underwent 44 Joshi's external stabilisation system procedures at the Central Institute of Orthopaedics at the Safdarjung Hospital, New Delhi, between January 1998 and December 1999 for the conditions of interest. Three-dimensional correction was achieved by use of the distractor device.

RESULTS

Excellent results were obtained in 77% of the cases, good results in 13%, and poor results in 9% of the cases. Complications in half of the cases were pintract infections, which eventually healed on an outpatient basis without any residual sequelae.

CONCLUSION

The Joshi's external stabilisation system frame is ideally suited for the child in whom clubfoot deformities remain uncorrected by plaster-of-paris casts and manipulation, as well as for recurrent clubfoot. Casting after complete correction not only protects the osteopenic bones while the pin-tracts heal, but also maintains correction and allows gradual weightbearing.

Для цитирования: Suresh S, Ahmed A, Sharma V K. Role of Joshi's external stabilisation system fixator in the management of idiopathic clubfoot.. Journal of orthopaedic surgery (Hong Kong). 2003. DOI: 10.1177/230949900301100216.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.