Spectra, fluence and absorbed doses in sensitive organs due to scattered X-rays during a chest CT.

Vazquez-Bañuelos Joel, Campillo-Rivera Guillermo Eduardo, Vega-Carrillo Hector Rene, Torres-Cortes Carina Oliva, Marquez-Mata Claudia Angelica, Vasquez-Arteaga Marcial

СтатьяПеревод в очереди

Аннотация

The use of ionizing radiation for the treatment and diagnosis of diseases is becoming more frequent. The technologies associated with diagnostic imaging are constantly evolving, allowing faster and cheaper diagnoses to benefit the patient. However, this has caused an increase in the exposure to ionizing radiation of patients and health professionals. One of the diagnostic techniques for obtaining high-resolution anatomical images of patients is computed tomography (CT). Due to the detail and quality of the images obtained with CT, its use is becoming more frequent. The information provided by these images allows the specialist to make better diagnoses; however, exposure to X-rays deposits a dose in the patient. CT represents approximately 20% of all X-ray examinations but it is responsible for 70% of the medical dose accumulated by the patient. During the acquisition of the images, the highest dose is deposited in the area of the body whose image is to be obtained. During the incidence of X-rays, there is dispersion of these that reach sensitive organs whose dose is not evaluated. The objective of this work was to estimate, using Monte Carlo methods, the fluence and X-ray spectra and to obtain a factor that allows knowing the absorbed dose in sensitive organs due to scattered radiation during a chest CT. With the MCNP5 code, the CT equipment and a hybrid anthropomorphic phantom, type BOMAB it was found that the absorbed dose in these organs depends on the size of the organ and the distance between the organ and the surface of the slice on the thorax where the X-rays are incident.

Для цитирования: Vazquez-Bañuelos Joel, Campillo-Rivera Guillermo Eduardo, Vega-Carrillo Hector Rene, Torres-Cortes Carina Oliva, Marquez-Mata Claudia Angelica, Vasquez-Arteaga Marcial. Spectra, fluence and absorbed doses in sensitive organs due to scattered X-rays during a chest CT.. Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 2023. DOI: 10.1016/j.apradiso.2023.110723.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.