MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/srep35069

Медицинская библиотека · Scientific reports · 2016

Microfluidics-based point-of-care test for serodiagnosis of Lyme Disease.

Nayak Samiksha, Sridhara Archana, Melo Rita, Richer Luciana, Chee Natalie H, Kim Jiyoon, Linder Vincent, Steinmiller David, Sia Samuel K, Gomes-Solecki Maria

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

Currently, diagnostic testing for Lyme disease is done by determination of the serologic responses to Borrelia burgdorferi antigens, with the exception of the early localized phase of disease where diagnosis must be done clinically. Here, we describe the use of microfluidics technology to develop a multiplexed rapid lab-on-a-chip point of care (POC) assay for the serologic diagnosis of human Lyme disease. Following ELISA screening of 12 candidate antigens, we tested 8 on a microfluidic diagnostic system, called mChip-Ld, using a set of 60 serological samples. The mChip-Ld test, which can be performed in 15 minutes at the point of care, showed promising performance for detection of antibodies to B. burgdorferi using the PPO triplex test (rP100 + PepVF + rOspC-K, AUC of 0.844) compared to a gold-standard reference of culture confirmed clinical samples. The performance is comparable to the commonly used C6 peptide by lab-based ELISA. In addition, the mChip-Ld test showed promising performance for early-stage diagnosis of the disease using the antigen OspC-K (sensitivity and specificity of 84% and 92%, respectively; AUC of 0.877). Overall, this study underscores the potential of using microfluidics to aid the diagnosis of Lyme disease at the point of care.

Для цитирования: Nayak Samiksha, Sridhara Archana, Melo Rita, Richer Luciana, Chee Natalie H, Kim Jiyoon, Linder Vincent, Steinmiller David, Sia Samuel K, Gomes-Solecki Maria. Microfluidics-based point-of-care test for serodiagnosis of Lyme Disease.. Scientific reports. 2016. DOI: 10.1038/srep35069.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.