MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmir.2024.101729

Медицинская библиотека · Journal of medical imaging and radiation sciences · 2024

A feasibility study of tumor motion monitoring for SBRT of lung cancer based on 3D point cloud detection and stacking ensemble learning.

Deng Yongjin, Qiu Minmin, Wu Shuyu, Zhong Jiajian, Huang Jiexing, Luo Ning, Lu Yao, Bao Yong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To construct a tumor motion monitoring model for stereotactic body radiation therapy (SBRT) of lung cancer from a feasibility perspective.

METHODS

A total of 32 treatment plans for 22 patients were collected, whose planning CT and the centroid position of the planning target volume (PTV) were used as the reference. Images of different respiratory phases in 4DCT were acquired to redefine the targets and obtain the floating PTV centroid positions. In accordance with the planning CT and CBCT registration parameters, data augmentation was accomplished, yielding 2130 experimental recordings for analysis. We employed a stacking multi-learning ensemble approach to fit the 3D point cloud variations of body surface and the change of target position to construct the tumor motion monitoring model, and the prediction accuracy was assess using root mean squared error (RMSE) and R-Square (R2).

RESULTS

The prediction displacement of the stacking ensemble model shows a high degree of agreement with the reference value in each direction. In the first layer of model, the X direction (RMSE =0.019 ∼ 0.145mm, R2 =0.9793∼0.9996) and the Z direction (RMSE = 0.051 ∼ 0.168 mm, R2 = 0.9736∼0.9976) show the best results, while the Y direction ranked behind (RMSE = 0.088 ∼ 0.224 mm, R2 = 0.9553∼ 0.9933). The second layer model summarizes the advantages of unit models of first layer, and RMSE of 0.015 mm, 0.083 mm, 0.041 mm, and R2 of 0.9998, 0.9931, 0.9984 respectively for X, Y, Z were obtained.

CONCLUSIONS

The tumor motion monitoring method for SBRT of lung cancer has potential application of non-ionization, non-invasive, markerless, and real-time.

Для цитирования: Deng Yongjin, Qiu Minmin, Wu Shuyu, Zhong Jiajian, Huang Jiexing, Luo Ning, Lu Yao, Bao Yong. A feasibility study of tumor motion monitoring for SBRT of lung cancer based on 3D point cloud detection and stacking ensemble learning.. Journal of medical imaging and radiation sciences. 2024. DOI: 10.1016/j.jmir.2024.101729.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.