MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/ac402975q

Медицинская библиотека · Analytical chemistry · 2013

Strong anion determination in biological fluids by capillary electrophoresis for clinical diagnostics.

de Macedo Adriana Nori, Jiwa Muhammad Irfan Yasin, Macri Joseph, Belostotsky Vladimir, Hill Stephen, Britz-McKibbin Philip

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

New methods for quantitative analysis of strong anions are required for diagnostic testing of human diseases. Current techniques suffer from poor selectivity and/or long analysis times that are not amenable for labile anions in high-saline or volume-restricted samples. We introduce a rapid assay (<5 min) based on capillary electrophoresis (CE) with indirect UV detection for simultaneous analysis of sulfate, sulfite, and chloride in human urine, plasma, and sweat specimens. Remarkable selectivity for strong anions is achieved by using an acidic background electrolyte under reversed polarity that results in electrokinetic rejection of matrix interferences at the capillary inlet. A dual co-ion probe system consisting of 5 mM naphthalene disulfonate (NDS) and 5 mM naphthalene trisulfonate (NTS) in 0.4 M formic acid, pH 2.0 is developed for detection of UV transparent anions (S/N ≈ 3, 60 μM with a 25 μm inner diameter fused-silica capillary) with good peak symmetry and baseline stability. Due to the chemical reactivity of sulfite, dilute formaldehyde is used as a reagent to form an acid-stable hydroxymethylsulfonate adduct. Method validation confirmed excellent linearity (R(2) > 0.999), good accuracy (mean bias ≈7%), and acceptable long-term reproducibility (CV < 10%) over 20 days. The assay allows for artifact-free determination of sulfate and sulfite with consistent results for chloride when compared to standard electrochemical methods (R(2) > 0.975). Preliminary data suggest that kidney-stone formers have lower urinary sulfate excretion relative to non-kidney-stone patient controls (p = 0.0261). CE offers a selective yet robust platform for routine analysis of strong anions that is needed for confirmatory testing of cystic fibrosis, sulfite oxidase deficiency, urolithiasis, and other disorders of sulfur metabolism and/or anion transport.

Для цитирования: de Macedo Adriana Nori, Jiwa Muhammad Irfan Yasin, Macri Joseph, Belostotsky Vladimir, Hill Stephen, Britz-McKibbin Philip. Strong anion determination in biological fluids by capillary electrophoresis for clinical diagnostics.. Analytical chemistry. 2013. DOI: 10.1021/ac402975q.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.