Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2022

Clinical predictors and implications of cardiac inflammation detected on positron emission tomography (PET) in patients referred for premature ventricular complex (PVC) ablation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chung Wei-Hsin, Hayase Justin, Do Duc H, Dixit Neal, Ajijola Olujimi, Buch Eric, Boyle Noel, Shivkumar Kalyanam, Bradfield Jason S

Аннотация

BACKGROUND: Positron emission tomography computed tomography (PET-CT) is not routinely used for premature ventricular complexes (PVCs). Whether specific clinical factors are associated with abnormal PET-CT results is not clear.

METHODS: The treatment courses and baseline characteristics of consecutive patients in a single center between 2012 and 2021, age > 18 years old, and who received 18F-fluorodeoxyglucose (FDG) PET-CT imaging for evaluation of PVCs were retrospectively analyzed.

RESULTS: A total of 102 patients was included. Of these, 27 patients (26.4%) had abnormal PET-CT and 61 (59.8%) had normal imaging. Abnormal PET-CT findings were associated with non-sustained ventricular tachycardia (NSVT) (95.2% vs. 52.6%, p = 0.001), higher number of PVC morphologies (2.29 ± 0.7 vs. 1.31 ± 0.6, p < 0.001), greater PVC coupling interval dispersion (72.47 ± 66.4 ms vs. 13.42 ± 17.9 ms, p < 0.001), and greater likelihood of fast heart rate dependent PVCs (78.5% vs. 38.2%, p = 0.017). Fourteen (51.8%) patients had an abnormal PET-CT and abnormal late gadolinium enhancement (LGE). Patients with abnormal PET-CT were more frequently treated with immunosuppression (81.4% vs. 3.2%, p < .0001) than with catheter ablation (11.1% vs. 45.9%, p = 0.002) compared to the normal PET-CT group. Over a median follow-up of 862 days (IQR 134, 1407), PVC burden decreased in both groups [from 23 ± 16% to 9 ± 10% (p < 0.001) in abnormal PET-CT group and from 21 ± 15% to 7 ± 10% (p < 0.001) in normal PET-CT group].

CONCLUSIONS: Abnormal PET-CT findings were more commonly associated with NSVT, multiform PVCs, greater PVC coupling interval dispersion, and fast heart rate dependent PVCs. LGE was not sensitive for detecting inflammation. Immunosuppression was effective in managing PVCs with abnormal PET-CT.

Предметные рубрики MeSH