MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0267659119850024

Медицинская библиотека · Perfusion · 2019

Pilot study evaluating a non-titrating, weight-based anticoagulation scheme for patients on veno-venous extracorporeal membrane oxygenation.

Deatrick Kristopher B, Galvagno Samuel M, Mazzeffi Michael A, Kaczoroswki David J, Herr Daniel L, Rector Raymond, Hochberg Eric, Rabinowitz Ronald P, Scalea Thomas M, Menaker Jay

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

There is no universally accepted algorithm for anticoagulation in patients on veno-venous extracorporeal membrane oxygenation. The purpose of this pilot study was to compare a non-titrating weight-based heparin infusion to that of a standard titration algorithm.

METHODS

We performed a prospective randomized non-blinded study of patients: Arm 1-standard practice of titrating heparin to activated partial thromboplastin times goal of 45-55 seconds, and Arm 2-a non-titrating weight-based (10 units/kg/h) infusion. Primary outcome was need for oxygenator/circuit changes. Secondary outcomes included differences in hemolysis and bleeding episodes. Descriptive statistics were performed for the continuous data, and primary and secondary outcomes were compared using Fisher's exact test as appropriate.

RESULTS

Six patients were randomized to Arm 1 and four to Arm 2. There was no difference in age, pH, PaO2/FiO2 ratio, peak inspiratory pressure, positive end expiratory pressure, mean airway pressure at time of cannulation, time on extracorporeal membrane oxygenation, or survival to hospital discharge in the two arms. Arm 1 had a statistically higher median activated partial thromboplastin times (48 (43, 52) vs 38 (35, 42), p < 0.008) and lower LDH (808 units/L (727, 1112) vs 940 units/L (809, 1137), p = 0.02) than Arm 2. There was no difference in plasma hemoglobin (4.3 (2.5, 8.7) vs 4.3 (3.0, 7.3), p = 0.65) between the two arms. There was no difference in mean oxygenator/circuit change, transfused packed red blood cell, or documented bleeding complications per patient in each arm (p = 0.56, 0.43, 0.77, respectively).

CONCLUSION

In this pilot study, a non-titrating, weight-based heparin infusion appears safe and as effective in preventing veno-venous extracorporeal membrane oxygenation circuit thrombotic complications as compared to a titration algorithm. Larger studies are needed to confirm these preliminary findings.

Для цитирования: Deatrick Kristopher B, Galvagno Samuel M, Mazzeffi Michael A, Kaczoroswki David J, Herr Daniel L, Rector Raymond, Hochberg Eric, Rabinowitz Ronald P, Scalea Thomas M, Menaker Jay. Pilot study evaluating a non-titrating, weight-based anticoagulation scheme for patients on veno-venous extracorporeal membrane oxygenation.. Perfusion. 2019. DOI: 10.1177/0267659119850024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.