MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1164/rccm.201907-1284oc

Медицинская библиотека · American journal of respiratory and critical care medicine · 2020

Pitolisant for Daytime Sleepiness in Patients with Obstructive Sleep Apnea Who Refuse Continuous Positive Airway Pressure Treatment. A Randomized Trial.

Dauvilliers Yves, Verbraecken Johan, Partinen Markku, Hedner Jan, Saaresranta Tarja, Georgiev Ognian, Tiholov Rumen, Lecomte Isabelle, Tamisier Renaud, Lévy Patrick, Scart-Gres Catherine, Lecomte Jeanne-Marie, Schwartz Jean-Charles, Pépin Jean-Louis, HAROSA II Study Group collaborators

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Rationale: Excessive daytime sleepiness is a common disabling symptom in obstructive sleep apnea syndrome.

Objectives

To evaluate the efficacy and safety of pitolisant, a selective histamine H3 receptor antagonist with wake-promoting effects, for the treatment of daytime sleepiness in patients with moderate to severe obstructive sleep apnea refusing continuous positive airway pressure treatment.

Methods

In an international, multicenter, double-blind, randomized (3:1), placebo-controlled, parallel-design trial, pitolisant was individually titrated at up to 20 mg/d over 12 weeks. The primary endpoint was the change in the Epworth Sleepiness Scale score. Key secondary endpoints were maintenance of wakefulness assessed on the basis of the Oxford Sleep Resistance test, safety, Clinical Global Impression of severity, patient's global opinion, EuroQol quality-of-life questionnaire, and Pichot fatigue questionnaire.Measurements and Main

Results

A total of 268 patients with obstructive sleep apnea (75% male; mean age, 52 yr; apnea-hypopnea index, 49/h; baseline sleepiness score, 15.7) were randomized (200 to pitolisant and 68 to placebo) and analyzed on an intention-to-treat basis. The Epworth Sleepiness Scale score was reduced more with pitolisant than with placebo (-2.8; 95% confidence interval, -4.0 to -1.5; P < 0.001). Wake maintenance tests were not improved. The Pichot fatigue score was reduced with pitolisant. The overall impact of pitolisant was confirmed by both physicians' and patients' questionnaires. Adverse event incidence, mainly headache, insomnia, nausea, and vertigo, was similar in the pitolisant and placebo groups (29.5% and 25.4%, respectively), with no cardiovascular or other significant safety concerns.

Conclusions

Pitolisant significantly reduced self-reported daytime sleepiness and fatigue and improved patient-reported outcomes and physician disease severity assessment in sleepy patients with obstructive sleep apnea refusing or nonadherent to continuous positive airway pressure.Clinical trial registered with www.clinicaltrials.gov (NCT01072968) and EU Clinical Trials Register (EudraCT 2009-017251-94).

Для цитирования: Dauvilliers Yves, Verbraecken Johan, Partinen Markku, Hedner Jan, Saaresranta Tarja, Georgiev Ognian, Tiholov Rumen, Lecomte Isabelle, Tamisier Renaud, Lévy Patrick, Scart-Gres Catherine, Lecomte Jeanne-Marie, Schwartz Jean-Charles, Pépin Jean-Louis, HAROSA II Study Group collaborators. Pitolisant for Daytime Sleepiness in Patients with Obstructive Sleep Apnea Who Refuse Continuous Positive Airway Pressure Treatment. A Randomized Trial.. American journal of respiratory and critical care medicine. 2020. DOI: 10.1164/rccm.201907-1284oc.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.